Laserfiche WebLink
IIII II� Customer No.: Anchor fastening design for Page: 2 of 3 <br /> Location: Quotation: <br /> Hilti Inc. BEAM TO WALL CONNECTION Project: HOWARD RESIDEN <br /> PO Box 21148 <br /> List No.: <br /> Tulsa,OK 74127 <br /> Phone:1�00�78-8000 Phone: Date: 10/22/98 <br /> Fax: 1-800-878-7000 Resp.:REF Name: REF <br /> Setting Details <br /> �� Kwi k Bolt I I - 1/2"x7 <br /> -,s a�=o�'>"�'�:a�'� '� <br /> 9 �.�,9 . '�q�A�a�q�. Tinst Recommended Rotary Hammer <br /> d0 � o Sw � TES, TE15, TE18-M <br /> �bi , po -�•�¢..�•o, <br /> s ::ga�t�gr�t�'� ` � Recommended Hilti Drill Bit <br /> hnom tfix �/2�� <br /> h� <br /> h Width across flats <br /> 3/4" <br /> tightening torque: <br /> hmin < h < hnom: 40 ft•Ib <br /> h >= hnom: 65 ft•Ib <br /> diameter of clearance hole: 9/16 in <br /> minimum member depth: 3 1/2" <br /> thickness of anchor plate: 0.32 in <br /> more details see packaging! <br /> Data arM results must be checked for agreement with the acWal e�tisting conditions and for plausibilityl <br /> HIDU-CC J2.2 O 1987 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hil�AG,Schaan <br />