FEYEREISEN & ASSOCIATES INC. 4037 WEST BROADWAY <br /> CONSULTING ENGINEERS MINNEAPOLIS,MINNESOTA 56422 <br /> • <br /> � TELEPHONE:612-537-4666 <br /> December 30, 1997 <br /> Alistate Insurance Inc. <br /> P.O. Box 1490 <br /> Minneapolis, Mn. 55440 <br /> Re: Claim o. 4 93 4134 <br /> 1300 Shorline Dr <br /> rono, n. <br /> Attn: Mr. Steve Prasser �� 5�� 3` �� <br /> Dear Mr. Prosser. <br /> At your request the undersigned has investigated the referenced fire loss claim for the purpose of <br /> determining the foundation condition and its adequacy for use in the rebuilding of this home. <br /> Date of loss is unknown to me at this time. <br /> This is a one story wood frame home with a tuck under 3 car garage. I would estimate the age of <br /> the original structure at about 60 yrears. The home would appear to have been added to several <br /> times. In fact there is an excavated area in the southwest corner indicative of an in progress � <br /> addition. I would not hazard a guess at the age of the additions. <br /> Damage to the superstructure inlcuded virtually the whole house. Damage to the lower level was <br /> not as extensive,with areas to the north and east undamaged. <br /> In my judgment the foundation walls can be used in the reconstruction of this home. This � <br /> recommendation is made subject to the following: <br /> 1. Presumably there is an architectural plan indicating the nature of the in progress work that is <br /> proposed to the southwest comer of the home. Further that this plan was subject to review by <br /> the Building Official and a building permit issued. Absent the foregoing, it is a condition that a <br /> building permit be obtained. (The existing wall footing has been exposed during the excavation <br /> f�r:h� aw�itEon i^ an �:nacceplw�lp mar.ner, i.e. the ex�ava!�on hws bee!? m��+e 5elqw an� <br /> immediately to the edge of the existing footing, excavations below existing footings should not <br /> come closer than 2 units horizontal for every unit of cut below the existing footing.) <br /> 2. Vertical separations in the exterior foundation wall were noted on the north and west <br /> foundation walls. These separations and any other cracks found should be repaired. <br /> 3. At the northwest comer of the home is an addition built over a crawlspace. The top of the <br /> concrete footing in this area is visible on the exterior. It must be ascertained that this footing <br /> does extend the minimum distance (3'-6'� below grade for frost protection. <br /> 4. At such time as the debris is cleaned out another inspection should be made to determine if <br /> other corrective work needs to done. <br />