1 <br /> � RHVAC-Residential&Light Commercial HVAC Lo ds Program * Elite Software Development,Inc. <br /> A-ABC Appliance&Heating Amy Lloyd <br /> � Minrleapolis,MN 55408 08-19-2004 Page 2 <br /> Project Summary <br /> Design Data <br /> Project Name: Amy Lloyd <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum. Drv Bulb Difference <br /> Winter: -10 N/A N/A 72 N/A <br /> Summer: 90 73 I 50% 75 32 <br /> Check Figures <br /> Total Building Supply CFM: 957 CFM per square foot: 0.251 <br /> Square feet of room area: 3,816 Square feet per ton: 1,604.778 <br /> Building Loads <br /> Total heating required with outside air: 73,714 Btuh 73.714 MBH <br /> Total sensible gain: 17,938 Btuh 73 % <br /> Total latent gain: 6,563 Btuh 27 % <br /> Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent) <br /> 2.378 Tons (based on 77% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> � <br />