Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
� o� <br /> O '�'a` O <br /> ��:==�=� CITY of ORONO <br /> v�1 ''������ �+ <br /> 'ql, !4 Munici Offices <br /> � � ��'. � <br /> � ���,i�,���, �ti <br /> .t9 `,��:��`�r�.�,g� Street Address: Mailing Addross: <br /> k�,+gg0 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> Owner: � Address: 2175 Shevlin Dr. <br /> Permit #'s: 2287 Dates: 10/14/69 Contractors: 8opkins P1bQ. <br /> (This is [x] an existing system [ ) new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Me�ts or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3O Non-Compliant Sy�tem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any s�tstem with less than three feet of vertical separation between the bottom <br /> � of the drainfield and the saturated soil level. <br /> (The saturated soil lmval (�] has or [ ] has not been identified at this tima. If the <br /> saturated soil level h�s not bean ideatified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> 1..� have not been pumped out within three years, they should be pumped out now. <br /> (DurinQ the last septic tank Maintenaace Pua�out the taaks [ ] were or (�] were not confirmed <br /> to be watertiQht by tha licansed put�iny coatractor. If tha tanks wara not coafirmed to be <br /> watertiQht, this classffication is subject to revision.) <br /> 1�INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medivm <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is required by 12/31/2007. <br /> �o'�()� � <br /> Dat� e of Inspection S tic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />