My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
S
>
Shevlin Drive
>
2160 Shevlin Drive - 03-117-23-34-0019
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:37:43 PM
Creation date
10/24/2018 1:24:51 PM
Metadata
Fields
Template:
x Address Old
House Number
2160
Street Name
Shevlin
Street Type
Drive
Address
2160 Shevlin Dr
Document Type
Septic
PIN
0311723340019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> CITY <br /> OF ORON �O� <br /> Municipal Offices O O <br /> Post Office Box <br /> Crystal Bay, MN 55323- 066 � � ON—SITE 3EWA(�E TREA'1'l�NT <br /> � . � IN3PECTION RF,PORT <br /> I �Z Gti <br /> 9kEsxo�'� <br /> Owner: L,r(X��I ���01�� Address:_�I� �x"d�iT'� i(Jr. <br /> Permit �'s: Dates: ��7�/3 Contractors: /iC/i/�°Y� �C� <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treat nt system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is�]- a existing system [ ] neu construction) <br /> SYSTEM CONFORMITT C1-3): <br /> 1 "CODE SYSTEM"-A s tem which meets all the location, design, and construction standards of the current City <br /> Codes, and whi h is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discha ging any pollutants into ground or surface waters. <br /> "CONFORMING SYSTE "-A system which does not meet all th,e location, design, and construction standards of the <br /> current City C es, but was installed according to th¢ code in effect at the time of installation, and which <br /> is operating s tisfactorily by treating and disposing'�,of the entire current sewage input without discharging <br /> any pollutants into ground or surface watgrs. <br /> 3 "NON-CONFORMING S STEM'�-A prohibited system; a system Ilocated within a designated 100-year floodplain; any <br /> system which y or may not meet all the location, design, and construction standards of the current City <br /> Codes and whic is failing for any reason; and any.sy�stem with less than 3 feet of unsaturated soil or send <br /> between the di tribution device and the limiting soil characteristics. <br /> (The limiting oil characteristic [ ] has or �] has mot been identified at this time. If the limiting soil <br /> characteristic has not been identified, this L�lassificetion may be subject to revision.) <br /> TANK CONDITION C5-10): +�— <br /> y-'t <br /> T�k inspection indicates:, <br /> Punpout not needed a this time. <br /> 6 Solids accunulation in tanks indicates they should be rxnped out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. 'fanks should be pumped out as soon as possible. <br /> 8 System is dischargin to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers mi sing-tanks could not be inspected. Inspection risers (4�� dia. pipe> must be instelled in each <br /> tank at next ut. lf tanks have not been punped out within the last three years, they should be punped <br /> out now. ' <br /> 10 Inspection pipe is lpcated directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have rrot been punped out within the last three years, they should be Fxmped out now. <br /> DRAINFIELD CONDITION 11-1 : <br /> Dr field inspection indi�ates: <br /> Drainfield is dry, n surfacing evident. <br /> �Some evidence of sur cing, rwt critical yet. <br /> 13 Drainfield is satur ted and visibly discharging untreated effluent to the surface. Contact the City inspector <br /> immediately. I�epairs must be completed uithin 90 days� <br /> 14 Drainfield extent arxi condition unknown. <br /> , <br /> LIMITING SITE FACTORS slo setbacks etc. : <br /> POTENTIAL FOR SYSTEM FAILUf�E (decends on soils,water table,etc.): j/yf,y�'�y..� <br /> �rujri� <br /> COMMENTS: <br /> , <br /> Date of Inspection ; eptic System Inspector <br /> Note: In the event that t is inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that his report does not guarantee or certlify that an existing system will continue to function <br /> properly� but is merely op�nion of the adequacy of the sysltem under current conditions based on the available <br /> information. <br /> This repo t must be kept on the premises with the system locetion and pumping records. <br /> WF�ITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.