Christine Mattson <br /> From: Adam Edwards <br /> Sent: Tuesday, November 28, 2017 2:13 PM <br /> To: Laura Oakden <br /> Cc: Christine Mattson; Roger Peitso <br /> Subject: RE: 2017-01543 1720 Shadywood Rd New Home <br /> Laura, <br /> I've reviewed the grading plan and offer the following comments: <br /> 1. I Concur with your comment about the County ROW permit being needed <br /> 2. The proposed driveway and construction entrance need to be moved off of the water gate valve or the gate <br /> valve will have to be redone to make it surmountable. Excerpt from water as built below. <br /> 3. Separate utility permits will be required for the sewer and water disconnection and connections. <br /> 4. The grade around the building area appears to be being raised around 2 feet. Special care will need to be <br /> exercised in creating the drainage pattern on the sides of the property to ensure that run off is not directed onto <br /> the neighboring properties. <br /> 5. Perimeter sediment control measures should be installed by the Contractor and inspected by the City prior to <br /> any work, including demolition. Contractor must provide minimum 24 hour notice prior to inspection. <br /> Adam <br /> � ���,,�- W C �,�C..� <br /> � <br /> � ��5�' <br /> 1��-e� -��e-- va��`Q-' �t -�-i �. o�-- <br /> � <br /> ��w�-w � n-s-t�- . <br /> C� . . <br /> � �, � �--�.� �2�4� �- <br /> � w ��s �, <br /> � <br />