Laserfiche WebLink
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON-SITE SEWA(�E TREAT�NT <br /> r�`„� �� INSPECTION REPORT <br /> G <br /> �9k'EsKo�'� <br /> �,/ , <br /> Owner:_!1'!l�/2V1/1 O�OS22/�Sk l Address: 356� Si X'f-!� /�.�E/�. �J`5�56� <br /> Permit #�'s: Datea: '--' Contractors: -"' <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is� an existing system [ ] neu construction> <br /> S1'STEM CONFORMITY (1-3): <br /> 1 ��COOE SYSTEM"=A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soit or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic�as or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been ident fied, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): q <br /> --i-- <br /> Tank inspection indicates: <br /> 5 Punpout not needed at this time. <br /> 6 Solids accunulation in tanks indicates they shoutd be pirriped out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next punpout. 1f tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 lnspection pipe is located directly over tank beffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punpea out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION C11-14): <br /> e field inspection indicates: <br /> 1 Orainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING S1TE FACTORS (sloce,setbacks.etc.): ���-�� <br /> POTENTIAL FOR SYSTEM FA[LURE (deaends on soils.water table.etc.): ��D/U/'9-� ����n�'l. <br /> COMMENTS: f Cjq y�i ct� G� y+1,�� Q✓?�ZCj �,�J <br /> � l . M <br /> 0 <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an optnion of the adequacy of the system under current conditions based on the evailable <br /> information. <br /> This report must be kept on the pre�nises with the system locstion and p�mping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeow�er <br />