My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-00029 - addn/remodel/repair
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2745 Shadywood Road - 21-117-23-31-0003
>
Permits/Inspections
>
2008-00029 - addn/remodel/repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:05:55 PM
Creation date
10/18/2018 1:32:04 PM
Metadata
Fields
Template:
x Address Old
House Number
2745
Street Name
Shadywood
Street Type
Road
Address
2745 Shadywood Road
Document Type
Permits/Inspections
PIN
2111723310003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Comments: <br /> ❑ Door 4:Glass,U-factor:0.320 <br /> Comments: <br /> ❑ Door 5:Solid,U-factor:0.420 <br /> Comments: <br /> ❑ Door 7:Glass,U-factor:0.320 <br /> Comments: <br /> ❑ Door 8:Glass,U-factor:0.320 <br /> Comments: <br /> 0 Door 9:Glass,U-factor:0.320 <br /> Comments: <br /> Floors: <br /> ❑ Lower Level floor:Slab-On-Grade:Unheated,4.0'insulation depth,R-5.0 continuous insulation <br /> Comments: <br /> Slab insulation to extend down from the top of the slab to at least 4.0 ft.OR down to at least the bottom of the slab then <br /> horizontally for a total distance of 4.0 ft. <br /> Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) <br /> insulation and extends at least 6 in.below grade. <br /> � Main Level floor:All-Wood JoisUTruss:Over Unconditioned Space,R-38.0 cavity insulation <br /> Comments: <br /> ❑ Media Room Floor:All-Wood Joist/Truss:Over Unconditioned Space,R-38.0 cavity insulation <br /> Comments: <br /> Air Leakage: <br /> ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. <br /> ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from <br /> combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. <br /> Vapor Retarder: <br /> ❑ Required on the wartn-in-winter side of all non-vented framed ceilings,walls,and floors. <br /> Materials Identiflcation: <br /> ❑ Materials and equipment must be installed in accordance with the manufacturers installation instructions. <br /> ❑ Materials and equipment must be identified so that compliance can be detertnined. <br /> ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. <br /> ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. <br /> Duct Insulation: <br /> ❑ Ducts in unconditioned spaces must be insulated to R-5.Ducts outside the building must be insulated to R-8.0. <br /> Duct Construction: . <br /> � All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), <br /> mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. <br /> Exception:Continuously welded and locking-type IongRudinal joints and seams on ducts operating at less than 2 in.w.g.(500 <br /> Pa). <br /> ❑ The HVAC system must provide a means for balancing air and water systems. <br /> Temperature Controls: <br /> ❑ Thermostats are required for each separate HVAC system.A manual or automatic means to partially restrict or shut off the <br /> heating and/or cooling input to each zone or floor shall be provided. <br /> Service Water Heating: <br /> ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integrai <br /> heat trap or is part of a circulating system. <br /> � Insulate circulating hot water pipes to the levels in Table 1. <br /> Circulating Hot Water Systems: <br /> ❑ Insulate circulating hot water pipes to the levels in Table 1. <br /> Page 6 of 8 <br />