Laserfiche WebLink
S/N 554 RIGHT-J SHORT FORM 2-24-g2 <br /> Job #: Htg Clg <br /> For: TOM HUBER Outside db -20 95 <br /> 2615 SHADYWOOD RD. Inside db 70 75 <br /> ORONO MN 55331 Design TD 90 20 <br /> 471-7104 Daily Range - M <br /> Inside Humid. - 50 <br /> By: COUNTRYSIDE HEATING & COOLING SERV. 'S Grains Water - 33 <br /> 10880 CO.RD. #20 <br /> DELANO MN 55328 Const. Quality a <br /> 446-1299 # of Fireplaces 0 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make CARRIER Make <br /> Model 58SSC090-GC Model <br /> Type NAT.GAS Type <br /> Efficiency / HSPF 80. 0 COP/EER/SEER 0. 0 <br /> Heating Input 110000 Btuh Sensible Cooling 0 Btuh <br /> Heating Output 89000 Btuh Latent Cooling 0 Btuh <br /> Heating Temp Rise 52 Deg F Total Cooling 0 Btuh <br /> Actual Heating Fan 1569 CFM Actual Cooling Fan 1569 CFM <br /> Htg Air Flow Factor 0. 020 CFM/Btuh Clg Air Flow Factor 0.053 CFM/Btuh <br /> Space Thermostat Load Sensible Heat Ratio 86 <br /> ----------------------------------- <br /> ROOM NAME � AREA � HTG � CLG � HTG � � CLG <br /> � SQ.FT. � BTUH � BTUH � CFM � CFM <br /> --------------------------------------------- <br /> BASEMENT #1 � 1066 � 13091 � 1066 � 264 � 57 <br /> BASEMENT #2 � 312 � 2645 � 0 � 53 � 0 <br /> PORCH � 312 � 17964 � 7151 � 362 � 382 <br /> LIV. ,DIN. ,KITCH. � 520 � 15215 � 10278 � 307 � 550 <br /> BED RMS. MAIN � 546 � 10444 � 4122 � 211 � 220 <br /> UPPER LEVEL #1 � 36 � 2170 � 827 I 44 � 44 <br /> UPPER #2 � 140 � 1289 � 446 � 26 � 24 <br /> UPPER #3 � 144 � 5201 � 1471 � 105 � 79 <br /> UPPER #4 � 168 � 3588 � 1532 � 72 � 82 <br /> UPPER #5 � 104 � 4499 � 1875 � 91 � 100 <br /> UPPER #6 � 98 � 1720 � 578 � 35 � 31 <br /> ----------------------------------------- <br /> Entire House � 3446 � 77826 � 29347 � 1569 � 1569 <br /> Ventilation Air � � 2970 � 0 � � <br /> Latent Cooling � I I 4822 I I <br /> --------------------------------- <br /> TOTALS � 3446 � 80796 � 34170 � 1569 � 1569 <br />