Laserfiche WebLink
Plan Review Notes <br /> April 14, 2010 <br /> 2477 Shadywood Road <br /> Page 2 of 2 <br /> Requirements: <br /> • Provide accessible parking plan <br /> • Revise accessible ramp to meet 1 to 20 slope within 30' setback <br /> • Handrails and guardrails on existing stairs must meet code <br /> • Slope on sidewalk to accessible ramp shall not exceed 1 to 20 slope <br /> • Door hardware shall be operable with one hand and not require tight grasping, pinching <br /> or twisting of the wrist <br /> • Door thresholds shall be no higher than '/2 inch <br /> • Accessible counters shall be provided where transactions or services are customarily <br /> provided <br /> • The means of egress, including the exit discharge, shall be illuminated at all times the <br /> building space served by the means of egress is occupied <br /> • Exist doors shall be readily openable from the inside without a key or any special <br /> knowledge or effort <br /> NOTE: <br /> Permit does not include trash and storage enclosure. Enclosure will need City Council approval <br /> and will be required to be moved to a conforming location. <br /> w:�street fites�.shadywood road�2477�p1an review notes.doc <br />