Laserfiche WebLink
A I t ro n i x� AL602ULADA, AL802ULADA, AL 1002ULADA <br /> ' NAC Power Extenders <br /> Rev AL602/802/1002ULADA-AOSI <br /> Overview <br /> The AL602ULADA,AL802iJLADA and AL1002ULADA are extremely cost <br /> ! effective voltage regulated remote NAC Power Extenders.They may be connected <br /> ��' to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications <br /> A include Notification Appliance Circuit (NAC) expansion (supports ADA <br /> _ �.r=,�, <br /> � �' requirements) and will provide auxiliary power to support system accessories. <br /> .�� z ' <br /> ��" p� AL602ULADA AL802ULADA AL 1002ULADA <br /> �� <br /> � � � • 24VDC or 12VDC • 24VDC or 12VDC • 24VDC rated <br /> rated @ 6.5 amp max. rated @ 8 amp max. @ 10 amp max. <br /> • Two(2)Class A or • Two(2)Class A or • Two (2)Class A or <br /> four(4)Class B outputs. four(4)Class B outputs. four(4)Class B outputs. <br /> AL602ULADAJ AL802ULADAJ AL1002ULADAJ <br /> • Larger enclosure. • Larger enclosure. • Larger enclosure. <br /> Saecifications <br /> • Two (2) Class A or two (2) Class B FACP inputs. • Temporal Code 3 Mode. <br /> • Two (2)NC dry contact trigger inputs • Steady Mode. <br /> (AL802ULADA and AL 1002LTLADA only) • Input to Output Follower Mode (maintains <br /> • Two (2) Class A or four(4) Class B synchronization of notification appliance circuits). <br /> indicating circuits. • March Time. <br /> • Two (2) Class B outputs may be paralleled for more • Compatible with 24VDC or 12VDC fire panels. <br /> power on an indicating circuit. • Common trouble inputs and outputs. <br /> • One (1)Aux. Power Output @ 1 amp supply current • Ground fault detection. <br /> (w/battery back up). • Input 115VAC. <br /> • Signal Circuit Trouble Memory- facilitates quickly • AC fail supervision (form "C" contacts). <br /> locating intermittent system trouble and eliminates • Low battery supervision (form "C" contacts). <br /> costly and unnecessary service calls. LED's indicate a • Battery presence supervision (form "C" contacts). <br /> prior fault (short, open, ground) has occurred on one • Power supply, logic board, red enclosure, cam lock, <br /> or more signaling circuit outputs. transformer& battery leads. <br /> • 2-wire Horn/Strobe Sync mode allows audible • Enclosure: <br /> notification appliances(Horns) to be silenced while - Combination knockouts re 1/2" and 3/4" <br /> visual notification appliances (Strobes) continue - Accommodates up to two (2) <br /> to operate. 12VDC/12AH batteries. <br /> • Horn/Strobe sync protocols include: Gentex�, <br /> System Sensor�, Faraday,Amseco. <br /> Agency Approvals <br /> UL Listed Control Units and Accessories <br /> U` for Fire Alarm Systems (UL 864), �� California State Fire Marshal Approved. <br /> UL Listed Standard for Safety for Fire <br /> Protective Signaling Systems (UL 1481). <br /> M EA NYC Department of Buildings Approved. FM Factory Mutual Approved. <br /> Approved �pp� <br />