Laserfiche WebLink
• �S • <br /> ��' BOSCH <br /> � <br /> Invented for life <br /> D8125MUX Multiplex Bus Interface <br /> J - ` ► Multiplex bus controls two independent buses <br /> OC � <br /> ov�, _ ;U� ��,., ��� ,. :+ ► Aux Power terminals that can be used for remote <br /> �,;� , -� '�" , k _ , devices <br /> ,�><<�_ - = � _ <br /> � ��'� �r/ �""''�.� �";_ 5' � ► Programmed with D5060 Handheld Programmer(not <br /> �f <br /> � . � - required for"i"class modules) <br /> a <br /> m ��`���.` ��'"� ���'� �+� � � �` ► Operation monitoring LED <br /> , , �, ��.� � � �;�.. �,�,� . <br /> �: ' '} �,,4�,�, 1 � i ► Connect to Zonex i or Zonex 2 <br /> � r �y,�l ` ; t' � ��"� ► Standard three hole mounting <br /> � <br /> � { ► Accepts Daisy Chain and T•Tapping bus configurations <br /> �� <br /> �� r��� . ° � <br /> The D8125MUX Multiplex Bus Interface Module and D5060 Hand-held Programmer <br /> associated modules are used to expand the compatible Use the D5060 Multiplex Point Programmer to program <br /> Bosch control panels beyond their standard number of multiplex bus points.The D5060 is not required when <br /> onboard initiating zones or points.The D8125MUX module programming"i"class modules. In addition to programming <br /> is installed in the control panel enclosure,and is connected points, use the D5060 to view the MUX device point <br /> to either Zonex 1 or Zonex 2 on the control panel where it number. <br /> scans the multiplex (MUX) points connected to it and <br /> reports the points' status to the control panel. Point index <br /> programming then determines if an action on the part of the Certifications and Approvals <br /> control panel is required (alarm response,trouble <br /> response, and so on). Region Certification <br /> USA UL AMCX:Central Station Alarm Units <br /> Functions (UL1610,UL1635),AOTX:Local Alarm <br /> Units(UL464,UL609),APAW:Police <br /> Two Independent Buses Station Alarm Units(UL365,UL464), <br /> The multiplex bus interface can control two independent APOU:ProprietaryAlarm Units(UL1076), <br /> buses.A fault on one MUX bus does not prevent the other NBSX:Household BurglarAlarm System <br /> from operating normally. Units(UL1023),UTOU:Control Units and <br /> Accessories-Household System Type <br /> Aux Power Terminals <br /> (UL985) Refer to D8125MUX Operation <br /> The D8125MUX has Aux Power terminals labeled PowerA andlnstallationGuide(P/N:36796)forUL <br /> (+,-) and Power B (+,-)that can be used for remote devices UOJZ:Control Units,System(UL864,9th <br /> that require an uninterrupted source of power. Up to edition) <br /> 200 mA are available at these terminals. CSFM 7167-1615:100,7165-1615:113, <br /> Note Observe correct polarity when connecting <br /> 7165-1615:119 <br /> devices to these power terminals. <br /> www.boschsecurity.com <br />