' � • � � • <br /> Certifications and Approvals Outputs <br /> Current(BURG bus): 550 mA maximum from control panel <br /> Region Certification Current(FIRE bus): 550 mA maximum from control panel <br /> USA UL UOXX:Control UnitAccessories,System powerRequirements <br /> (UL864,9th edition) <br /> CSFM 7165-1615:119 Control Unit Current: 30 mA maximum <br /> (Non High-Rise) Voltage(supply): 12.0 VDC nominal <br /> Installation/Configuration Notes Ordering Information <br /> Mounting Considerations ICP-SDI-9114SDISplitter ICP•SDI-9114 <br /> Note ULrequiresthattheSDlsplitterbemountedin Providestheabilitytosetuptwoindependent <br /> SDI buses from a single SDI connection on the <br /> the same enclosure with the control panel, or control panel. <br /> in a separate enclosure in the same room <br /> within 20 ft (6.0 m) of the control panel and <br /> connected by conduit. <br /> Wiring Considerations <br /> Wiring from the control panel to SDI splitter should be <br /> 0.8 mm(22 AWG)to 2.0 mm(12 AWG)wire with a maximum <br /> wire length of 6.0 m(20 ft).The maximum impedance of the <br /> wire from the control panel to the SDI splitter must not <br /> exceed 1 f2. <br /> The maximum total wiring length for any single bus is <br /> 3048 m (10,000 ft).To determine the maximum impedance, <br /> maximum wire length and appropriate wire gauge for wiring <br /> from the SDI splitter to the SDI devices, refer to the <br /> specifications for each SDI device. <br /> Parts Included <br /> �uant. Component <br /> 1 SDI splitter <br /> 1 Hardware pack <br /> 1 Literature pack <br /> Technical Specifications <br /> Environmental Considerations <br /> Relative Humidity: 93%maximum,non-condensing <br /> Temperature(operating): 0°C to+50°C(+32°F to+122°F) <br /> Mechanical Properties <br /> Dimensions(H x W x D): 127 mm x 74 mm x 25.4 mm <br /> (5 in.x 2.9 in.x 1 in.) <br /> Weight: 0.13 kg(4.6 oz) <br /> Amarlcas: Europa,Middla East,Africs: AsirPacfflc: Represe�tW by <br /> Bosch Security Systems,Inc. Bosth Security Systems B.V. Robert Bosch(SEA)P[e Ltd,Securi[y Systems <br /> 130 Perinton Parkway P.O.Box 80002 11 Bishan Street 21 <br /> Fairport,New York,14450,USA 5600 JB Eindhoven.The Netherlands Singapore 573943 <br /> Phone:+1 800 289 0096 Phone:r 31 40 2577 284 Phone:+65 6571 2600 <br /> Fax:*1 585 223 9180 Fax:+31 40 2577 330 Fax:+65 6571 2698 <br /> security.sales@us.bosch.com emea.securitysystems�bosch.com apr.securitysystems@bosch.com <br /> www.boschsecurity.us www.boschsecurity.com www.boschseturity.com <br /> �Bosch Security Systems Inc.20101 Data subject to change without notice <br /> T41802411631 Cur:en-US,V7,7 Jan 2030 <br />