� � <br /> International Ministerial Fellowship <br /> Plumbing <br /> Plan No.PLB 1005-00052 <br /> Page 3 . <br /> June 16,2010 <br /> appropriate ASTM designations by the manufacturer. <br /> g. The installation must be in accordance with the manufacturer's installation instructions. <br /> 12. If plastic pipe is used for the drain,waste and vent system: . <br /> a. PVC plastic pipe shall comply with ASTM Standard D2665,D2949, or F891. <br /> b. It must be installed in accordance with Minnesota Rules,part 4715.0580(F)and part 4715.0600. <br /> Above-grade horizontal runs of plastic waste and vent pipe cannot exceed 35 feet in totallength. <br /> Above-grade vertical stacks conshucted of plastic pipe may exceed 35 feet in total height only if an <br /> approved expansion joint is used. <br /> c. Solvent weld joints in PVC pipe must include use of a primer which is of contrasting color to the pipe <br /> and cement(see Minnesota Rules,part 4715.0810, subpart 2). <br /> 13. No more than two water closets may be served by a 3-inch horizontal waste pipe(see l�iinnesota Rules,part <br /> 4715.2310). <br /> 14. The plumbing system shall be tested in accordance with Minnesota Rules,part 4715.2820. <br /> 15. The water distribution system shall be disinfected in accordance with Minnesota Rules,part 4715.2250. <br /> NOTE(S): <br /> 1. The scope of this project consists of the remodelling of an existing building. The plumbing installation <br /> includes three water closets,a urinal,three lavatories, a drinking fountain, and a wall hydrant. <br /> 2. T'his facility will be served by existing municipal water and sewer service connections. <br /> Authorization for construction in accordance with the approved plans may be withdrawn if cons�truction is not <br /> undertaken within a period of two years. 'I'he fact that the plans have been approved does not necessarily mean that <br /> recommendations or requirements for change will not be made at some later time when changed conditions, <br /> additional information,or advanced knowledge make improvements necessary. <br /> Approved: <br /> , ' �� <br /> Bra.dley C. rickson <br /> Public Health Engineer <br /> Plumbing Plan Review and Inspections Unit <br /> 651/284-5880 <br /> cc: Tonka Plumbing Heating&Cooling Inc <br /> Proform Thermal Systems <br /> City of Orono Building Official <br />