My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01042 - fire systems
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2445 Shadywood Road - 20-117-23-11-0015
>
Permits/Inspections
>
2016-01042 - fire systems
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:47:29 PM
Creation date
10/10/2018 12:33:19 PM
Metadata
Fields
Template:
x Address Old
House Number
2445
Street Name
Shadywood
Street Type
Road
Address
2445 Shadywood Road
Document Type
Permits/Inspections
PIN
2011723110015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L-�v��.,�� �j- / - /�-, <br /> �r1�O City of Orono FOR CITY USE ONLY �� <br /> �"1 P.O.Box 66 Date Received: ���1�� Permit# � � �L (_/Z <br /> , • � 2750 Kelley Parkway � - , � - . �s-7 �, <br /> Crystal Bay,MN 55323 Amount: � — ,��� /.�-? <br /> a �, � (952)249-4600 <br /> y� ; Approved By: ❑Charge Plan Review <br /> L <br /> �'�kFs�p��' Recommends: A roval Denial ❑ <br /> CITY OF ORONO—FIRE ALARM OR <br /> KITCHEN EXTINGUISHER/GENERAL PERMIT <br /> (All permits must be approved by the Firc�'[nrshall and/or Building Official) <br /> 1. All fire alarm systems, voluntary or required by Minnesota State Building Code (MUBC)or <br /> Minnesota State Fire Code (MUFC) shall be installed and maintained as per National Fire Protection <br /> Association(NFPA) 72 and 72E, 1996 edition,National Electrical Code and manufacturers <br /> requirements. <br /> 2. Permits are required for all fire alarm system installations. Permits can be obtained from the City of <br /> Orono- Building Official at, 2750 Kelly Parkway Orono, MN or via phone (952) 249-4600. <br /> Permits are also available online at: www.ci.orono.mn.us <br /> 3. Two sets of plans and specification sheets shall be submitted to the Orono Fire Marshal for approval <br /> at feast 7 �����rkin� days before start of installation and shall include: <br /> a. Specification data sheets on all components of system. <br /> b. Floor plans indicating locations of devices, fire alarm control panel, sub-panels, transponders, <br /> enunciator, interconnecting wiring and zoning. <br /> c. Power connections including source and branch circuit data. <br /> d. Type of back up power system. <br /> e. Fire alarm control panel shall be compatible with all devices. <br /> f. All components of the system shall be UL or FM listed for their applications. Smoke <br /> detectors shall be listed for commercial/industrial use. <br /> 4. All systems shall be addressable. Smoke detectors shall be photo-electric. No combination <br /> burglar/fire alarm systems are allowed unless approved by the Orono Fire Marshal. <br /> 5. Power supply for the system shall include battery back-up with a UL listed fire alarm panel. Alarm <br /> verification is required for all systems using smoke detectors. <br /> 6. The alarm system shall be audible above the ambient noise level in all areas of the building. <br /> Audio/visual signaling devices are required. <br /> 7. When central station notification is required or provided it must be through a UL or FM listed <br /> communicator or control panel. <br /> 8. If a smoke detecting system installed in the tenant space of a building is directly connected to the <br /> building fire alarm panel, then <br /> a. A zone on the alarm panel must identify the tenant space or zone of the building that the <br /> system is located(i.e., second floor, west wing). <br /> b. A visual annunciation light shall be installed on the corridor side of the main door of the <br /> tenants space and activate when the detection system in the tenants space activates. <br /> 9. The system shall be tested in the presence of the Orono Fire Marshal for final approval. <br /> Appointments can be made by calling the Fire Marshall at(952) 473-9701, <br /> 24-hours notice is requested. The test will include: <br /> a. Random testing of system devices. <br /> b. Random testing for system trouble and ground fault trouble. <br /> c. Correct operation of back-up power system. <br />
The URL can be used to link to this page
Your browser does not support the video tag.