Laserfiche WebLink
5. Allowable Soil Bearin Pressure 1500 sf assumed er IBC 17. Install and com act backfill in lifts not exceedin 12 inches. a � � � <br /> THESE PLANS AND SPECIFICATIONS ARE g p � � p p g � <br /> Table 1804.2) Backfill shall be compacted to 95% standard proctor density � � � <br /> E)CP�RESSLY STRUCTURAL REQUIREMENTS FOR � � <br /> vTHIS PROJECT AND ARE DEVELOPED FROM DESIGN CODES: unless noted otherwise by soils engineer. Soils supporting � ..�- � ,n w <br /> .INFORMATION PROVIDED. 1. 2015 Edition of the Minnesota State Building Code. exterior slabs�or parking lots shall be compacted according to o $ o � <br /> soils engineer s requirements. <br /> � OUR INV4LVEMENT IN THE DESIGN OF THIS GENERAL FOUNDATION 8� CAST-IN-PLACE 18. No part of the structure shall be placed on frozen soil. �� � <br /> �STRUCTURE IS LIMITED TO THE INDIVIDUAL CONCRETE NOTES: 19. Maintain frost depth for all footings. Extend footings to bear � Z <br /> MEMBERS ADDRESSED AND SPECIFIED IN THiS GENERAL on natural soils or engineered fill. � ' c = <br /> REPORT. ALL OTHER ENGINEERING AND DESIGN = <br /> 1. All construction shall be done under the supervision of a 20. Contractor shall be responsible to keep the foundation and soil �� � � <br /> REMAINS THE RESPONSIBILITY OF OTHERS. qualified,experienced concrete contractor. within the building area from freezing during below-freezing �e��a �' <br /> STRUCTURAL NOTES: 2. All construction shall be performed in accordance with design construction. � n�� <br /> GENERAL: codes of the American Concrete Institute, Concrete 21. Contractor shall be responsible to implement cold weather ���€t � <br /> Reinforcing Steel Institute Manual of Standard Practice, and concrete requirements as per ACI 306. E�� N � <br /> 1. All construction shall be done in accordance with the good construction practice. ';�i� � <br /> 22. Contractor shall be responsible to implement hot weather 9 <br /> Minnesota State Building Code. S�p <br /> 3. The contractor is to coordinate all underground mechanical concrete requirements as per ACI 305. w <br /> 2. Contractors shall verify all dimensions and conditions on site piping and ductwark elevations with the mechanical contractor " � <br /> 23. All door opening sizes and locations are to be verified. � � w <br /> before construction is begun. All observed discrepancies shall and adjust footing elevations as necessary to conform. �� o < <br /> be reported immediately. 24. All concrete shall be protected from premature drying and �' � <br /> STEEL REINFORCEMENT freshly placed concrete shall be protected against wash by rain. <br /> 3. Structural members including foundations, walls, trusses, 4. "ACI Code of Standard Practices" is to govern fabrication of c <br />� floors, beams, columns, etc. aze designed for "in-place" loads. STRUCTURAL STEEL: <br /> all reinforcing steel. y � <br /> Contractor is responsible for shoring and bracing, without e <br /> 5. Cast-in- lace concrete shall be installed er ACI 318 and ACI 1. Provide structural steel bolts, anchor bolts, misc. parts; weld a� � <br /> overstressing, all structural elements as required at all stages of p P plates and inserts as shown on the plans and as required for this 1° Z �°�^ m <br /> construction until completion of this project. 301. Install all inserts,dowels,etc. as indicated on plans. � �, ���'�,� <br /> buildin g pro ject. o z ��a g <br /> M W uiz�� y <br /> DESIGN LOADS' 6. Wall reinforcing shall be securely tied in place and floor y � ��o�� <br /> � reinforcing shall be properly supported on chairs. 2• All welding shall be by qualified welders and shall conform to a � N �� � <br /> 1. Roof: Dead Loads: 10 psf(top chord) the AWS 5.1 or 5.5. � � � � ;;:�, <br /> U � d c x co <br /> 10 psf(bottom 7• Reinforcing supplier is to provide all accessories, chairs, 3. All anchor bolts shall be ASTM F 1554 or equal. � � �"a LL a <br /> chord) spacing bars and supports necessary to secure steei in � �, � <br /> accordance with"ACI Detailing Manual"latest edition. 4. Ins t a l l (2) ve rtica l re bars (o f same size as wa l l rein forcing) a t � <br /> Live Load(snow load): 35 psf each side of each opening. Install lintels as specified below: � <br /> 8. Lap all reinforcing bars a minimuxn of 40 bar diameters and a <br /> 2. Floor: Dead Loads: 125 psf stagger splices. . Steel Lintels: Steel lintels of sizes indicated shall bear <br /> Live Loads: 50 sf 9. Bend all horizontal reinforcing bars a minimum of 24" around a minimum of 8"on each end,on 1/2"x 6"wide x 8" <br /> P long bearing plates with(2)5/8"diameter x 6"headed <br /> all corners. <br /> 2,000 Concentrated studs. Weld one end of beam to plate with 1/4"x 4" <br /> Load per IRC R601.5 10. Provide minimum concrete protection for all reinforcement as fillet weld each side of beam. Provide other end(at <br /> per section 7.7 of ACI 318 with the following minimum control joint)with side clips which provide lateral <br /> 3. Wind load: 90 mph(exposure B) re uirements for cast in lace concrete: Z <br /> q P support and allow longitudinal movement. <br /> DESIGN STRESSES: . Cast against and permanently exposed to earth 0 - <br /> l. Concrete at 28 days 3" � Q Z <br /> . Footings f'c=5000 . Exposed to earth and weather#5 bars and smaller W � � � <br /> psi 1 '/z" V' p w U <br /> . Foundation f'c=4000 • Exposed to earth and weather#6 bars and larger 2" � O Z � <br /> psi CONCRETE PLACEMENT Q � Z � <br /> 2: Reinforcing 11. All footings are centered under foundation walls and columns � � � <br /> � . Reinforcing bars ASTM A-615 Grade 60 Fy=60 ksi above,unless otherwise shown. � Q � � <br /> 3. Structural Steel 12. Contractor shall design forms for construction of concrete Z � O U <br /> ` . Anchor bolts ASTM F1554 Ft=20 k s i walls. Construct forms to the exact sizes, shapes, lines, and (n <br /> - dimensions shown, level and plumb. � � � <br /> , . Misc. structural steel ASTM A36 Fy= N � W <br /> 36 ksi 13. Do not allow the concrete to drop more than 4 feet into the N � <br /> ` forms. � <br /> . Structural steel beams,ASTM A992 Fy= � <br /> 50 ksi 14. Place concrete in the forms in horizontal lifts of not more that <br /> 2 feet and at a rapid enough rate to prevent formation of"cold <br /> • Welds=American Welding Society(AWS)A5.1 or �o��» <br /> A5.5 and E70XX electrodes <br /> 15. Vertical wall construction joints may be used if required by <br /> 4. Structural Lumber construction techniques,but are not mandatory. <br /> . Sills and all other lumber in contact with concrete or SHEET <br /> 16. Shore all foundation walls appropriately (or backfill each side �� <br /> masonry-treated#2 S.Pine(See STRUCTURAL equally)befare backfilling and compacting. <br /> WOOD for treating requirements.) oF s <br />