My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: foundation findings for remodel
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2264 Shadywood Road - 17-117-23-43-0124
>
Correspondence
>
Re: foundation findings for remodel
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:43:07 PM
Creation date
10/4/2018 11:27:42 AM
Metadata
Fields
Template:
x Address Old
House Number
2264
Street Name
Shadywood
Street Type
Road
Address
2264 Shadywood Road
Document Type
Correspondence
PIN
1711723430124
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Prapased�temodel of Existing Residence <br /> Ulteig Pmject No.207.1528 <br /> 3l4J200Q <br /> Page 4 <br /> 7��r diarneter ancl�or boIts r�t 72" on-center spacing minimum per the Code aiong the <br /> yerimeter of the existing foundation faotprir�f. <br /> b. The new bearing poinfs alang the front wall at approximately 3'-Q" in from <br /> the exterior wails will require (�)-£uIt height #4 vertical reinfvrcing bar to be <br /> piaced in each of the thre� cores directly beneath the bearing studs. The top <br /> full course of existing znascmry to remain is to consist of a bond beam with <br /> (2)#4 rein#orcing bars running a minimum vE 3'-0" zn each directian from the <br /> bearing paint. <br /> c. The exishng strip foating witl be structuralty adequate to support the new <br /> laads as described above without underpinning or oversizing. The contractc�r <br /> is to #ield verify the existing foundation masonry walls are 12-inchea wide, <br /> ar►d the sfxip footing exte�ds a minimum o£ 4-inches on each side of the <br /> faundation walI. <br /> �. Duc to the heigltt of the wafer faUle trt this area, iE is recornt�rended tkat the slrrh-on- <br /> grade haue a uapor tetarder and granuiar material Uelow to better rmprove the <br /> �erformance and lifrspan of tlze new siaU-art grade floor. <br /> P$.O�SSIONAt OPI�„ION <br /> 3. It is our professional engineering opinion that the proposed remodel wil� be <br /> adequately supported by the existing Eoundahon pravided �he proposed <br /> mod.ifications are made to the existing foundation wall. The overat� condition of the <br /> structure is very gocxi cansidexing its age. It should be expected that the existing <br /> Eoundatian will set#le under tihe new loading coriditions and soiI backfilling <br /> introduced from the remod�l/addition. Refer t�o AET's soi! boring report for rnare <br /> detailed analysis regarding settletrrent issues and reeommendations. <br /> GE1tTERAt <br /> 4_ The in€ormation, observations, and opinians stated ir► this report are based on an � <br /> inspecfion made by Dan Sargeant, PE and Nick Hanson. The inspe�tiom m�sisbed o# <br /> a visual walk-through of the basement level observing exposed elements and those <br /> accessible without the removat of Einished materials. � <br /> 5. The observaEions and opinions expressed in this report are based on our <br /> professional engineering judgment and professi�nal practice, as well as the visual <br /> inspecfion. Notify the engineer immediaFely if field condi.tions vary from those <br /> described in Ehe repor�. � <br /> � <br /> i <br /> I <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.