Laserfiche WebLink
��� 4. � � <br /> � � <br /> New Construction Energy Code Compliance Certificate � <br /> Per N I 101.8 Building CeRificate.A building certificate shatl be posted in a pertnanently visible location inside Date Certificate Posted <br /> the building. The certificate shail be completed by the bwlder and shall list infortnation and values of � . <br /> co nents listed in Table Nll01.8. Z/ZZ��O <br /> Mailing Address of the Dwelling or Dwelling Unit Orono.MN <br /> 2»2 s��(y c�;o�� ���� . . <br /> Name of Residential Contractor MN License Number <br /> True North Homes Z�'6 3 6 ��3 � <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> o � <br /> c <br /> a `' Active(With fan and monometeror <br /> �' � T othe�system monitoring device) <br /> `° = � ° Y <br /> w � a� at o- <br /> R <br /> '� Q Q� � � U dj 'O C <br /> � O ui vi O � � � T <br /> V <br /> Insulation Location � � z � � � o � W o <br /> a o �° °.° E E <br /> � � � � .n � b-0 W <br /> � � � <br /> � _ ,Z� i�.. i.�. w° w° � ci: u: Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall X Typeinlocation:intenoreutenororintegral <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation) X Typeinlocation:intenorexleriororintegral <br /> Rirtl JOISt(1't FIOOf+) R-19 X �nterior <br /> wall R-19 X <br /> Ceiling,flat R-44 X <br /> Ceiling,vaulted R-44 X <br /> Bay Windows or cantilevered areas X <br /> Bonus room over garage R-38 X <br /> Describe otherinsulated areas <br /> Windows 8 Doors eafing or Cooling DucTs Outside Condifioned Spaces <br /> Average U-FacCor(exC/udes Sky/ights and one door)U: 032 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coetlicient(SHGC): 029 R-value <br /> MECHANICAL SYSTEMS Make-up Air Se%ct a Type <br /> Applianees Heating System Domestic Water Heater Cooling System Not required per mech.code <br /> Fuel Type Natural Gas Natural Gas Electric PasS��e <br /> M anufactu re r Powered <br /> Interlocked with exhaust device. <br /> M ode I Describe: <br /> Input i� Capaciry in Ou[put in Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> Heat C.oss: Heat Location of duct or system: <br /> Structure's Calculated Gain: <br /> 90"/o SIiBR: <br /> C'alcula[ed <br /> E ff I Ci E fl C coolin�load: C fm's <br /> "round duct OR <br /> Mechanical VentilaKon System "metal duct <br /> Describe any addi[ional or combined heating or cooling systems if installed:(e.g.two fumaces or air Combusfion Air SBIeC(a rype <br /> ource heat pump with gas back-up fumace): Not reyuired per mech.code <br /> Se%ct Type Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cCms: <br /> Locatio�of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in efms: "round duct OR <br /> 1'otal ventilation(intermittent+continuous)rate in cfms: "metal duct <br />