Laserfiche WebLink
. 7 <br /> . � CASE 2-�EPARATED MIXED OCCUPANCIES(508.4) <br /> Using Table 503, identiiy the allawable height and area of each of the separated occupancies within the building. Con- <br /> struction types that provide, for each story of the building, tabular areas (as modified by Section 506) which result in a <br /> sum of the ratios of 1.00 or less and allowable heights (as modified by Section 504) equal to or greater than the actual <br /> height of the occupancy are permitted. <br /> Ac�al Adjusted Actual Allowabls <br /> Story Group floor area floor area* height height <br /> ft= � � ft stories ft stories <br /> � <br /> ft2 �ft�.__„�� ft stories ft stories <br /> ft� ft2 ���t=��stories ft stories <br /> _��__....._..�.�_._ ft- stories ft <br /> -- � --� stories <br /> --- ft f ft ft stories ft stories <br /> - - ft� ft� ft stories ft stories <br /> ft� ft stories ft stories <br /> Area ratio(single floor)= E Adjusted floor area• _ + �. + - <br /> i <br /> � Allow.tab. area, A�(Table 503j - - s�•� <br /> •AdJusted 11oor area=actual floor area+oorneraton inclor <br /> CHECK ALLOWABLE AREA(506.5) <br /> Three stories or less buildings ,�� Permitted types of construcdon <br /> Four or more story buildings �/ � �f Type of oonstruction assumed �_ � <br /> (Total area ratio 5 3) (^ �_ for review (602.1) ,� <br /> / <br /> Compliance verified i.----� <br /> MEZZANINES (505) <br /> Area limitation (505.2.1) Openness (505.2.3) <br /> Egress(505.2.2) � �_Equipment platforms (505.3) <br /> UNLIMITED AREA BUILDINGS (507�_- ""� ' <br /> .- <br /> Nonsprir�ldered, one story (507.2) �,-_�"Group H occupancies (507.8) <br /> Sprinklered, one story (507.3) �- Aircraft paint hangar(507.9) <br /> Two story(507.4) , .� -�'.- _ Group E buildir�gs (507.i0) <br /> Reduced open space (507.5) - � MotiorLpacture theaters (507,i 1) <br /> Group A�buildings (507 6, 507.� Covered and open mall buildings/anchor <br /> stores (507.12) <br /> SPECiAL PROVISIONS (510) <br /> Special condition applicable (510.1) Compliance verified <br /> SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY (Chapter 4) <br /> COVERED MALL AND OPEN MALL BUILDINGS (402) <br /> Open space (402.1.1, 402.12�;�,� Plastic signs (402.6 4) <br /> Lease plan (402.3) S�andpipe�system (402.7.1) <br /> Area/type of constn�ction (402.4.i) � �Smoke control (402.7.2) <br /> Fire separations (402.4.2-402.42.3) '�—' —Standby power and emergency voice/alarm <br /> Open mall construction (402.4.3) "\, (402.7.3, 402.7.4) <br /> Automatic sprinkler system (402.5) ��F.�re department access (402.7.5) <br /> Interior finish (402.61) Mall lid�i (402.$1) <br /> Kiosk requirements (402.6.2) Occupar�t lo�d (402.8.2-402.8.2.4) <br /> Playground structures (402.6.3);' Egress (402.8.3-402.8J) <br /> �" Security grilles and doors (402.8.8J <br /> -5- <br />