My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Flammable liquids Fire code review
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2500 Shadywood Road - 20-117-23-11-0034
>
Misc
>
Flammable liquids Fire code review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:48:06 PM
Creation date
9/25/2018 11:00:39 AM
Metadata
Fields
Template:
x Address Old
House Number
2500
Street Name
Shadywood
Street Type
Road
Address
2500 Shadywood Road
Document Type
Misc
PIN
2011723110034
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Cargill Fresh Water Biological Institute <br /> 6/11/98,page 5 <br /> ' relief discharge back to the drum, use pump suction or be provided with <br /> over-pressure relief. The transfer piping system uses a gas pressure system. <br /> � Only inert gas can be used. <br /> IIL All piping,hoses and valves used with the liquid transfer operations shall be <br /> listed or approved for the use. <br /> � N. The transfer system shall be electrically bonded between the drum and <br /> piping system. <br /> 8. The electrical classi�cation for where the flammable liquid will be transferred shall <br /> � be rated as Class I, division 2 for the entire pit area. All areas within 5 feet of any <br /> edge of any pumps,bleeders, withdrawal fittings, meters and similar devices shall be <br /> Class I, division 2 in all directions from the hazard. Since the transfer of liquids is <br /> � not to be located within the pit, all equipment within 3 feet of the floor areas, within <br /> 25 feet of the transfer pumps or similar equipment shall be protected with Class I, <br /> division 2 electrical equipment. <br /> � 9. Vehicles will be allowed for unloading and loading purposes in the pilot lab area. <br /> ' S.0 CONCLUSION <br /> Based on the supporting data and the information provided by Jafvert Mueller Architects, the <br /> proposed occupancy classi�cations of Group H-3 for the flammable liquid storage room and <br /> ' classification of Group B for the research and development area are conect in the opinion of The <br /> MountainStar Group, Incorporated. With the limitations and protection measures as outlined <br /> above, the laboratory and flammable liquid rooms will be protected in accordance with the <br /> � requirements and intent of the 1994 UBC and 1997 UFC. This report contains MountainStar's <br /> recommendations regarding the fire protection design required for dispensing and storage of the <br /> Class I-B flammable liquid in the flammable liquid storage room and for closed use and storage <br /> ' in the laboratory. <br /> This report will need to be re-evaluated, if the amount of liquid storage changes, quantity of <br /> ' liquid used in open or closed condition, liquid or hazardous material classification changes, <br /> storage arrangement is modified, or the fire rating which subdivides the space changes. Please <br /> contact us if you have any questions ar concerns. <br /> ' Prepared by: Approved y: <br /> ' l� _' � / <br /> � ; <br /> i`�� ' <br /> , Christopher Leaver Mic ael A. O'Hara, P.E. <br /> Fire Protection Specialist President <br /> � � [hereby certify that this plan,specification,or report <br /> was prepared by me or under my direct supervision <br /> and that I am a duly Registered Professional Engineer <br /> under the laws the State of Minnesota. <br /> ' Date Registration No.24067 <br /> ' <br /> ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.