My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1996-008441 - new septic system
Orono
>
Property Files
>
Street Address
>
S
>
Shadowood Drive
>
2335 Shadowood Drive - 27-118-23-32-0019
>
Septic
>
1996-008441 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:20:36 PM
Creation date
8/22/2018 12:09:50 PM
Metadata
Fields
Template:
x Address Old
House Number
2335
Street Name
Shadowood
Street Type
Drive
Address
2335 Shadowood Drive
Document Type
Septic
PIN
2711823320019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� . _ , <br /> ' Ejj�,2SF.LECTION PRnCEDURE <br /> A. Determine pump capacity: ' <br /> .�+. <br /> Gravity Distrlbudon aro �oRnraH of A �ow►rrEo u►�an� <br /> 1. Mintmum suggested is 600 gallons per hour(10 gpm)to stay ahead of ��.w, <br /> water use rate. <br /> � d� <br /> 2. Maximum sugg�ested for del�very to a drop box of a hon�e system is 2,700 <br /> gallons per hour(45 gpm)to prevent build-up of pressure in drop box. ;�`i,�,,,,,,:,,,,�,�., �� "�°����►rae►k�«�.- <br /> �,...,. .. . �i M1•rro M��w~arl 'i`°�aN <br /> hfla Ita�prN MOri[aMolly <br /> Psessure Distrtbution � �. r�� <br /> 3. a. Select number of perforated laterals � �a• ' , w� ��o�a• <br /> b. Select p erforation s p a c in g: 3 ft. . ��.:...• � r«r�n�:i��.c.� <br /> c. Sub t 2 ft.from the rock layer length. �,:; ��•�a«w uw► °e/eni���� • <br /> ����'2 ft.= 3S•Sft. �•�',����. �..,�;�:;y;;;s:.;;; . <br /> ����s�nnd <br /> d. Determine the number of s�aces between perforations. <br /> Length perf.spacing= 3S�S ft.+ 3 ft._ �1 spaces TAa�.s O�r�tpow►'riav n�nRG�s�nt c.r�t <br /> e. �� spaces+1=,_�rforations/lateral <br /> ' f. MulNply perforations per lateral by number of laterals to t-ra�a rerto�.ao�dt�ca Wu�) <br /> �t total mber of orations. ' , � <br /> � x�_�perforaHons. �" �• <br /> Z <br /> �.a � os6 oaa <br /> g' � X�'��p'Y'. i.�ob o� Qa <br /> 2.S 0.89 1.17 <br /> SELEC`TED PLJMP CAPACITY ��- m 3A o.98 t.28 <br /> �gp 4A 1.13 1.47 <br /> s.o i.� �.6s <br /> B.Determine head requisements: ���A������ntlal sy�e� <br /> 1. Elevation difference between py�np and point of discharge. �����,d���bw�en�s <br /> _�r feet <br /> 2. If pumpIng to a pressure distribudon system,add five feet for pressure <br /> required at manifold <br /> �feet � <br /> 3. FrlcNon loss . I�pe L.en8ch . <br /> � a. Enter frlcHon loss table with gpm and pipe diameter. Po;nt of Diacharge <br /> Read friction loss in feet per 100 feet from table. <br /> F.L._�ft./100 ft of pipe pevadon Difference <br /> b. Uetermtne total pipe length from pump to discharge . p,,,,,p <br /> poin� Add 25 percent to pipe length for fitHng . <br /> 1�or use a Htting loss chart. Equivalent pipe F-18b <br /> length-1.?S dt�s Pipe lettgth a 1.S inch 2.0 inch 3.0 inch <br /> _C�D x 1.25= ' 7s feet gp,,, �uonw��.iaoaor�. <br /> c. Calculate total hiction loss by multiplying <br /> � fricHon loss in ft/100 R by equivalent pipe length. i2 0.9 0.2�8 <br /> . Total triction loss= _ �� x �S- +100=�feet 14 1.28 0.38 <br /> 4. • Total he�d required is the sum of elevatlon difference, 16 1.63 0.48 <br /> s i head uirements,and total fricdon loss. 18 2.03 0.60 <br /> �' ''� 20 2.a� 0.�3 o.ii <br /> ' 23 3.73 I.11 0.16 <br /> �_+ s - + 1.� 30 5.23 1.SS 0.23 <br /> (1) (2) (3c1 � 7.� 2.06 0.30 <br /> 40 11.07 2.64 0.39 <br /> 43 14.73 3.28 0.48 <br /> TOTAL HEAD ��feet SO • 3.99 O.S8 <br /> SS 4.76 0.70 <br /> 60 5.60 0.82 <br /> C. Pwnp selection <br /> 1. A pump nnust be selected to deliver at least S3 gpm (Step A) � ,� <br /> with at least 1�_feet of total head (Step B). <br /> . • • _ <br />
The URL can be used to link to this page
Your browser does not support the video tag.