Laserfiche WebLink
=o-��. <br /> � . � <br /> ., o � <br /> o�;, <br /> �� �� � � . CITY of ORONO <br /> <.'''`P,�,�.. ,�,� : . <br /> +�l ,,'; . _ , � <br /> '�! �,. �,,ti. ,, �, Municipal Offces <br /> �'� " .1�' `;t�'ti G~ Street Address: �15a-a4q"y6o 0 Mailing Address: <br /> �9kE8H0¢� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �3�`U S�.Sd o''`� c) �� a r_ <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. <br /> T'he on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1�"CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failiag or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chuacteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �61Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> ���Tank was last pumped ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter discharee aut of septic svstem to orolons life of drainfeld. Ask aumaer to test <br /> slarm float to verifv alarm is still workine in vour house. The alarm warns owner that seata¢e is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> COMMENTS: �b v r� �l o a�5 ��, � J►�-� Sc�3:L �S-�.n�f:j a�tt <br /> ��f �r--rF' � �I e�CS . <br /> �:Z��a� �� <br /> Date of Inspection Matt Bolterman - Septic System [nspector <br /> Note: In the event that this inspection report is used to satisti' the requirements for a inortgage or u[her transfer of propertJ. be advised that this rep�rl docs <br /> nut �uarun�ee or eertit'� that an e�isting s�•stem ���ill continiie to funetion properh•. but is merel� an opinion of th� adequac� of the s�stem un�)rr currcnt <br /> cun�itiun>based on the availab(c inlonnation. <br />