Laserfiche WebLink
-O ��� <br /> � . �V' <br /> ; O O'�. <br /> ,,, <br /> ��' �� . CITY of ORONO <br /> ,,.,,.rs;r,-,� � . <br /> �a ��• � . <br /> ��' �, >,i�" ,, �, �. Municipal Off ces <br /> =i .';�: � <br /> �� ', '��•.�,'+';'' �-`��' G~ Street Address: qsa'a4q'�6� � Mailing Address: <br /> t'9x��p'4�'�' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: � �� `S��OwdO� �r- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> YSTEM CONFORMITY 1-3 : I <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failiag or an imminent threat to public health or safery. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or conshucdon stan�ards of the current Orono Municipa]Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): S� <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �I'�-��3 ). <br /> Make sure septic tanks are pumped throush manhole and not throu¢h white inspection pipes. This allows for the proper <br /> cleanin¢ Keep water softner and iron filter dischar¢e out of seatic svstem to prolons life of drainfield. Ask oumaer to test <br /> alarm float to verifv alarm is still workine in vour house. The alarm warns owner that septa¢e is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : � <br /> Drainfield is d�y,no surfacing evident. <br /> 9 Some�vidence of surfacing,not criticai yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediztely.Repairs must be completed within 90 days. <br /> COMMENTS: !`^�v��/ �"' S c�l�-� }��kl I D d}C 0�� <br /> °\2�—d'� ��``� ,� <br /> Date of Inspection Matt Bolterman - Septic S��stem Inspector <br /> Not�: In the event that this inspection report is used to satisf}'the requirements for a mortgage or uther transfer of propert�. be advised that this repur�does <br /> nut ��uar.intee ur certih that an esisting s�•stem ���ill continue tu funetion properlJ•, but is mereh an opiniun of the adequae:} of the s�•stem un�er current <br /> .un�itiun;based on the a��ailablc infurmation. <br />