<br /> � Total Buildin Summa Loads
<br /> _� E . M'� x . £ � o � e� �,� ��_ F a
<br /> �.
<br /> 3D Window Double Pane Low Emit Wood Frame 199 5,891 0 3,582 3,582
<br /> 11C Door Metal Polystyrene Core 42 1,619 0 367 367
<br /> 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 2216 9,995 0 2,266 2,266
<br /> 15G Wall 5'or More Below Grade 8/12" BIk+R-11 739 2,605 0 0 0
<br /> i 161 Ceiling R-44 Insulation 1901 3,585 0 1,705 1 705
<br /> 21A Basemt Floor 2'or More Below Grade 1896 3,731 0 0 0
<br /> Subtotals for structure: 27,426 0 7,920 7,920
<br /> People: 6 1,380 1,800 3,180
<br /> Equipment: 300 1,200 1,500
<br /> I Lighting: 0 0 0
<br /> Ductwork: 6,567 0 0 0
<br /> Infiltration: Winter CFM: 161, Summer CFM: 215 14,123 4,531 3,445 7,976
<br /> i Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336
<br /> � Sensible Gain Total: 15,806 �
<br /> � Temperature Swing Multiplier: X 1 15
<br /> Total Building Load Totals: 55,992 8,106 18,177 26,283
<br /> I �3�.�'ds���,�,��., : .,,..,,.�� � �n �,:,d ,«M, � :��� _:� �, �,s„
<br /> „,� , . �..' �.;..� , ..� ,.. :
<br /> Total Buildmg Supply CFM: 902 (1.7 AC/hr) CFM Per Square ft.: 0.237 y
<br /> Square ft. of Room Area: 3,797 Square ft. Per Ton: 1,293
<br /> , _r.. ,�. � � .., ,. .,... .7.<
<br /> �,.� „.
<br /> Total Heating Required With Outside Air: 55,992 Btuh 55.992 MBH
<br /> i Total Sensible Gain: 18,177 Btuh 69 %
<br /> , Total Latent Gain: 8,106 Btuh 31 %
<br /> Total Cooling Required With Outside Air: 26,283 Btuh 2.19 Tons (Based On Sensible+ Latent)
<br /> I 2.94 Tons(Based On 77% Sensible Capacity)
<br /> , ��, - .�
<br /> , :�. . s .. . � {{'�� ��_ �, ��. .F,��. ,. �'... ..,
<br /> � Calculations are based on 7th edition of ACCA Manual J.
<br /> � All computed results are estimates as building use and weather may vary.