RHV�Ir=Residel�al S�i,igh�Cortimet'�ia l�NAG.�.oads �� g � ¢�„` � � x � ��lite Sa'�Cware�i►slo ment,lnc
<br /> Ph+mouth Plumbmg 8`"He�ting : John Te�,nr,� c�sS�',�460 S nds�nrte'�Ln
<br /> B�c�okf�i: Cenfer.MN ���8-1662 ` � ::�, ,�,�.�� Pa '[
<br /> �ota/Building Summa Loads
<br /> 3
<br /> .s"; ,.: "�-. �l ' « � 5t .
<br /> �E
<br /> �
<br /> 3D Window Double Pane Low Emit Wood Frame 199 5,891 0 3,582 3,582
<br /> 11 C Door Metal Polystyrene Core 42 1,619 0 367 367
<br /> 121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 2216 9,995 0 2,266 2,266
<br /> 15G Wall 5'or More Below Grade 8/12" BIk+R-11 739 2,605 0 0 0
<br /> 161 Ceiling R-44 Insulation 1901 3,585 0 1,705 1,705
<br /> 21A Basemt Floor 2'or More Below Grade 1896 3,731 0 0 0
<br /> Subtotals for structure: 27,426 0 7,920 7,920
<br /> People: 6 1,380 1,800 3,180
<br /> Equipment: 300 1,200 1,500
<br /> Lighting: 0 0 0
<br /> Ducfinrork: 6,567 0 0 0
<br /> Infiltration: Winter CFM: 161, Summer CFM: 215 14,123 4,531 3,445 7,976
<br /> Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336
<br /> Sensible Gain Total: 15,806
<br /> Temperature Swing Multiplier: X 1.15
<br /> Total Building Load Totals: 55,992 8,106 18,177 26,283
<br /> Total Building Supply CFM: 902 (1.7 AC/hr) CFM Per Square ft.: 9 0.237
<br /> Square ft. of Room Area: 3,797 Square ft. Per Ton: 1,293
<br /> Total Heating Required With Outside Air: 55,992 Btuh 55.992 MBH
<br /> Total Sensible Gain: 18,177 Btuh 69 %
<br /> Total Latent Gain: 8,106 Btuh 31 %
<br /> Total Cooling Required With Outside Air: 26,283 Btuh 2.19 Tons(Based On Sensible+ Latent)
<br /> 2.94 Tons(Based On 77% Sensible Capacity)
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.
<br /> C:\Elite\Rhvacw\Projects\John Terrance Homes-2460 Sandstone Ln-Orono.rhv Thursday, January 15, 2004, 3:23 PM