Laserfiche WebLink
M <br /> Uponor Page 1 � <br /> STONEBAY TOWNHOMES-One Head Calculation (H.2) Date 4/13/2016 <br /> HYDRAULIC DESIGN INFORMATION SHEET <br /> Name - STONEBAY TOWNHOMES Date - 4/12/16 <br /> Location - ORONO MN <br /> Building - RESIDENTIAL System No. - 1 <br /> Contractor - PRECISION PLUMBING Contract No. - 19495F 003 <br /> Calculated By - PATRICK BROWN Drawing No. - F100 <br /> Construction: (X) Combustible ( ) Non-Combustible Ceiling Height VARIES <br /> OCCUPANCY - RESIDENTIAL <br /> S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D <br /> Y Number of Sprinklers Flowing: (X) 1 ( )2 ( ) 4 ( ) <br /> S ( )Other <br /> T ( )Specific Ruling Made by Date <br /> E <br /> M Listed Flow at Start Point - 17 Gpm System Type <br /> Listed Pres. at Start Point - 12 Psi (X) Wet ( ) Dry <br /> D MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction <br /> E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle <br /> S Additional Flow Added - Gpm Make LF SENJU SPRINKLER Model RC-RES <br /> I Elevation at Highest Outlet - 129 Feet Size 7/16 K-Factor 4.9 <br /> G Note: Temperature Rating 162 <br /> N <br /> Calculation Gpm Required 17 Psi Required 47.4 At Ref Pt STR <br /> Summary C-Factor Used: Overhead 150 Underground 150 <br /> W Water Flow Test: Pump Data: <br /> A Date of Test - x Rated Cap. <br /> T Time of Test - x @ Psi <br /> E Static (Psi) - 62 Elev. <br /> R Residual (Psi) - 61 Other <br /> Flow (Gpm) - 1055 <br /> S Elevation - 100 <br /> P Location: x <br /> P <br /> L Source of Information: x <br /> Y <br /> Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 <br />