|
� .� REc�r�r�Q
<br /> h r
<br /> �/ . �� .. . _ .. .. . .
<br /> �' AK��A C1TY OF ORONC� k,� �„ ��.����..�� :
<br /> tir
<br /> e�c nENom mxonucroa wiooi�c
<br /> PRODUCT DESCRIPTIOFY contents of the bag in a wheel-barrow;
<br /> Akona�Crack-Resistant Surface Bonding bucket, mortar box, or mechanical mixer. 4
<br /> Cement is a specially-formulated, multi- Mix product thoroughly to achieve a stiff, � ...,..
<br /> use product. It can be used to build and Putty-like consistency. Avoid high speed ��., � �, ,
<br /> restore retaining walis or block walls, mechanical mixing which can entrap air �# i ..�� e � ,
<br /> patch large vertical holes where �nto the mixture. If the product becomes , ,, _ ' , ,,� �F^�: ,� ;,;
<br /> non-sagging cement is a must; or repair firm before application, re-mix to proper ���„� �
<br /> consistency. If required, add additional
<br /> deteriorated stucco. Because it contains �:«"" ���.,. � �.,,,r
<br /> special fibers it will not shrink, crack, or Water sparingly, up to a total of 1'/z gal. ;��� � ' ,.'-�
<br /> (5.7 L)liquid per 50 Ib. (22.7 kg) powder. •►��«•+���-•Ww,� "»�%� �. .�
<br /> sag on a vertical repair. Provides -�
<br /> additional overall strength vs.
<br /> conventional concrete. Optional: For improved durability, _-
<br /> strength, and adhesion when applying �r 4� �;q '
<br /> � fi-
<br /> over previously coated and non-porous ^���=��g `F� ����'
<br /> YYHEN/YYHERE TO USE surfaces it is recommended to use Akona `�``�' • •������`
<br /> . Repair deteriorated concrete walls Concrete Bonding Additive in place of
<br /> • Patch deep vertical holes water(sold separately). Concrete Bonding
<br /> • Restore damaged concrete, masonry, Additive may be diluted by up to '/3 with often with water and use a "light touch"
<br /> and stucco water, however, for extra difficult when finishing the surface. Do not over
<br /> • Bonds dry-stacked masonry walls restoration or waterproofing projects, it is trowel. Protect the surface from use until
<br /> recommended to be used at full strength. patch is completely hard and set. Clean
<br /> ADVANTAGE� up with soap and warm water as soon as
<br /> • Moisture resistant APPLICATION application is completed.
<br /> • Glass fiber reinforced for durability Apply only to surFaces that are frost-free
<br /> . Hi h stren th Bonding Dry-Stack Segmental
<br /> 9 9 and above 40°F (4°C) and below 100°F Retainin Walls&Mason Walis:
<br /> • Controls shrinkage, cracking, and (38°C) within 24 hours of application and g �
<br /> sagging on vertical repairs 72 hours thereafter. Dampen the wall • Footings or Foundations: The secret
<br /> • Just mix with water or a bonding surface prior to applying product with a to sound structure is a strong, level
<br /> additive and use water spray. If the wall becomes dry foundation. A level and properly aligned
<br /> before application of product, re-wet the footing makes stacking and troweling
<br /> AVAILABLE SIZE wall. The dampened walis are important in much easier. Footings must be built
<br /> • 50 Ib. (22.7 kg)bag (BOM#102614) establishing a strong bond. below the frost line and should a be a
<br /> minimum of twice the thickness of the
<br /> �`s' blocks used. Consult our local
<br /> COVERAGE �" � Y
<br /> �� masonry supplier for information about
<br /> One 50 Ib. bag covers approximately 50 ' ` footings and slab construction.
<br /> sq. ft. at'/8 in. (3 mm)thickness • Dry-stacking Masonry Units: Lay the
<br /> ,,-� first course of masonry units in a full
<br /> SURFACE PREPARATION � bed of Crack-Resistant Surface
<br /> i � +�' Bonding Cement. Make sure this course
<br /> Read all directions before starting work. ` �'
<br /> Remove all loose or unsound materials. '���°-� �k�;.;; ° - " is straight and level. Dry-stack masonry
<br /> `"�+y� I,� � "'' ' '�6����� �' • units in a staggered or running bond
<br /> Thoroughly clean surface of dirt, dust, ��''''� ° pattern for strength. As you place
<br /> grease, paint or other contaminants masonry units in position, slide it
<br /> before building or restoring walls. against the masonry units below to
<br /> PRE-WET SURFACE JUST PRIOR TO Patching or Filling Holes in Concrete/
<br /> Mason Walls&Stucco Re air smooth out any roughness. Crack-
<br /> APPLICATION OF PRODUCT. ry p ' Resistant Surface Bonding Cement can
<br /> Crack-Resistant Surface Bonding Cement be used between masonry units to
<br /> MIXING is ideally suited for patching or filling holes maintain a level and properly aligned
<br /> in concrete or masonry walis, as weil as,
<br /> Begin with approximately 1 gal. (3.8 L) of repairing cracks or filling openings in Wall. The better you are in maintaining a
<br /> clean, cool water per bag. Mix complete stucco walls. Apply up to %2 in. (1.3 cm) �evel and aligned wall, the stronger and
<br /> more attractive your finished wall will
<br /> thickness per layer. Deep repairs may be. Dry-stack the rest of the wall before
<br /> require applying product in multiple lifts or applying the Crack-Resistant Surtace
<br /> � ��j layers after initial set between lifts gonding Cement to both sides of the
<br /> .?'' �� (approximately 2-4 hours), product should Wall. Apply product with a trowel in
<br /> ciaeaer trrse ��em��e� 6ieres be firm, but not final set. Make sure to upward strokes, maintaining a uniform
<br /> � dampen the surface area between thickness of at least '/e in. (3 mm). Do
<br /> applications of product. When troweling, not over-trowel.
<br /> � � be sure to clean the surface of the trowel
<br /> S�fet�6lfsses Naad Ml�er teref Tnwel
<br />
|