Laserfiche WebLink
Basement Wali 1: Wood Frame 40 11.6 4.3 2 <br /> Wail height: 8.0' <br /> Depth below grade: 4.0' <br /> ` Insulation depth: 8.0' <br /> Floor 2: All-Wood Joist/Truss,Over Unconditioned Space 219 29.7 1.4 7 <br /> Floor 1: Slab-On-Grade:Unheated 224 5.0 167 <br /> Insulation depth: 4.0' <br /> Furnace 1: Forced Hot Air, 92 AFUE <br /> Air Conditioner 1:Electric Central Air, 10 SEER <br /> Proposed and Maximum U-Factor Averages <br /> Proposed Ma�cimum <br /> Average U-Factor Aliowed U-Factor <br /> Above-Grade Windows and Glass Doors 0.263 0.370 <br /> Includes Foundation Windows>5.6 ft2 <br /> Floors Over Unconditioned Space 0.031 0.033 <br /> COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,specifications, <br /> and other calculations submitted with the permit applicadon. The proposed building has been designed to meet the 2000 Minnesota <br /> Energy Code requirements in REScheckVersion 3.5 Release ld (formerly MECchec/�and to comply with the mandatory <br /> requirements listed in the REScheckInspection Checklist. <br /> � <br /> Builder/Designer ��_ Date %0 �� � �� <br />