My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2003-P07037 - mechanical
Orono
>
Property Files
>
Street Address
>
S
>
Sandstone Circle
>
653 Sandstone Circle - 33-118-23-11-0031
>
Permits/Inspections
>
2003-P07037 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:43:19 PM
Creation date
8/6/2018 11:30:20 AM
Metadata
Fields
Template:
x Address Old
House Number
653
Street Name
Sandstone
Street Type
Circle
Address
653 Sandstone Circle
Document Type
Permits/Inspections
PIN
3311823110031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RH'�dC-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc. <br /> ' Plymouth Plumbing&Heating John Terrence Homes-3 units inside uni <br /> , Brookl n Center, MN 55428-1662 Pa e 1 <br /> Total Building Summa Loads <br /> Component Area Sen Lat Sen Total <br /> Descri tion Quan Loss Gain Gain Gain <br /> 3D Window Double Pane Low Emit Wood Frame 175 5,180 0 3,150 3,150 <br /> 11 C Door Metal Polystyrene Core 42 1,618 0 368 368 ! <br /> 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 2532 11,420 0 2,590 2,590 <br /> � 15G Wall 5' or More Below Grade 8/12" BIk+R-11 299 1,055 0 0 0 <br /> 161 Ceiling R-44 Insulation 1043 1,967 0 936 936 <br /> 19J Floor Over Basement/Encl Crawl Carpet+ R-30 563 808 0 0 0 <br /> 21A Basemt Floor 2' or More Below Grade 480 945 0 0 0 <br /> Subtotals for structure: 22,993 0 7,044 7,044 <br /> � People: 6 1,380 1,800 3,180 <br /> Equipment: 300 1,200 1,500 <br /> � Lighting: 0 0 0 <br /> Ductwork: 2,799 0 0 0 � <br /> Infiltration: Winter CFM: 108, Summer CFM: 144 9,438 3,028 2,302 5,330 <br /> Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 <br /> Sensible Gain Total: �3 �g� ; <br /> ' Temperature Swing Multiplier: X 1.15 <br /> Total Building Load Totals: 43,106 6,603 15,855 22,458 <br /> i Check Fi ures <br /> Total Building Supply CFM: 665 (1.9 AC/hr) CFM Per Square ft.: 0.259 <br /> Square ft. of Room Area: 2,566 Square ft. Per Ton: 1,073 <br /> Buildin Loads <br /> Total Heating Required With OutsideAir: 43,106 Btuh 43.106 MBH <br /> Total Sensible Gain: 15,855 Btuh 71 % <br /> Total Latent Gain: 6,603 Btuh 29 % <br /> Total Cooling Required With Outside Air: 22,458 Btuh 1.87 Tons (Based On Sensible + Latent) <br /> 2.39 Tons (Based On 77% Sensible Capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> I I <br /> � <br /> i <br /> C:\Elite\Rhvacw\ProjectslJohn Terrance Homes - 3 unit inside unit.rhv Tuesday, September 16, 2003, 10:19 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.