My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00847 - new structure
Orono
>
Property Files
>
Street Address
>
S
>
Sandhill Drive
>
530 Sandhill Drive - 33-118-23-24-0020
>
Permits/Inspections
>
2017-00847 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:38 PM
Creation date
8/2/2018 12:44:50 PM
Metadata
Fields
Template:
x Address Old
House Number
530
Street Name
Sandhill
Street Type
Drive
Address
530 Sandhill Drive
Document Type
Permits/Inspections
PIN
3311823240020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhyac-F�,e�identlal 8 iight Conuner+clal HVAC Loads Elibe 8Mtvvare Duveloprnent,lnc. <br /> Sabre Plurnbing&Heaan9 � , 78b0>8adow <br /> P mou N 5447 _ P 2 <br /> Pro'ect Re ort —� <br /> . , . <br /> ��� _ <br /> Project Title: 7800-Barlow <br /> Designed By: Michael Hoium <br /> Project Date: Monday, May 16, 2016 <br /> Client Name: David Weekley Homes <br /> Company Name: Sabre Plumbing& Heating <br /> Company Representative: Michael Hoium <br /> Company Address: 15535 Medina Road <br /> Company City: Plymouth, MN 55447 <br /> Company Phone: 763-473-2267 <br /> Company Fax: 763�73-8565 <br /> � . �..W <br /> . . . Y u <br /> : . r . v � , n _ . , ,� �.p,. . <br /> � <br /> , � . - <br /> �., , <br /> }., � <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> �Bulb Wet Bulb $�1.�iUII7 $gLHU�] Dly Bulb Difference <br /> Winter: -15 -12.38 n/a 30% 72 29.40 <br /> Summer: 88 73 50°� 50% 75 35 <br /> Total Building Supply CFM: 1,264 CFM Per Square ft.: 0.257 <br /> Square ft. of Room Area: 4,912 Square ft. Per Ton: 1,728 <br /> Volume(fta)of Cond. Space: 46,672 <br /> Total Heating Required Including Ventilation Air: 57,137 Btuh 57.137 MBH <br /> Total Sensible Gain: 27,942 Btuh 82 % <br /> Total Latent Gain: 6,162 Btuh 18 °� <br /> Total Cooling Required Including Ventilation Air: 34,104 Btuh 2.84 Tons(Based On Sensible+Latent) <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are perfonned per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> Monday, May 16, 2016, 10:05 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.