My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P10476 - new septic system
Orono
>
Property Files
>
Street Address
>
S
>
Salem Court
>
2140 Salem Court - 27-118-23-31-0012
>
Septic
>
2006-P10476 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:19:38 PM
Creation date
8/1/2018 2:24:57 PM
Metadata
Fields
Template:
x Address Old
House Number
2140
Street Name
Salem
Street Type
Court
Address
2140 Salem Court
Document Type
Septic
PIN
2711823310012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' - University of Minnesota Pump Selection Procedure - 10125/04 <br /> All boxed�ctangles must be entered,the rest will be calculated. <br /> OMs�,�e <br /> 1. Determine pumP capacity: T��,,.t <br /> A. Gravity Distribution P"�"""' <br /> 1.Minimum required discharge is 10 gpm <br /> 2.Ma�dmum suggested discharge is 45 gpm <br /> j For other establishments at least 10%greater than the water j j <br /> supply rate,but no faster than the rate at which efAuent will flow <br /> out of the distribution device. <br /> B. Pressure Distribution-see pressure desiyn worlcsheet �ou t`�t"�"T SY�re`T' <br /> &poinf of discharge <br /> 7:ki7i6t7 F131f.E1 <br /> Selected Pump Capacity: �gpm rorai�pe <br /> leng <br /> 2A.etevatlon <br /> 2. Det�mine Total Dynamic Head(TDH) inlet diiference <br /> Wpe ;: --- - - - ' <br /> A Elevation differerx�beM�een pump and point of discharge. ' ` <br /> , <br /> Ft.................... .. 1 <br /> 25 feet '• --------------------------- ------ <br /> B. Special head requirement?(See Figure-Special Head Requirements) <br /> �5 feet Special Head Requiremenis <br /> Gravity Distribution Oft <br /> C. Fricbon loss in supply pipe Pressure Distribution 5ft <br /> 1. Select pipe diameter �2 in <br /> 2. En�Fgure E-9 wiTh gpm(1A or B)and pipe diameter(C1) <br /> Read fiic1i�on loss in fcet 100 feet from Figure E-9 E-9 Friction Loss in Plastic Pipe <br /> c n <br /> Friction bss= 3.99 �/100 ft of pipe r 100 ft <br /> nominal <br /> 3.Determine total pipe length from pump discharge to soil system discharge point. Flow Rate i e diameter <br /> Estimate by adding 25 percent to pipe lengfh for friction bss in fittings. 1.5° 2.0" 3' <br /> Pi times 1.25=equivalent pipe length <br /> 275 ft x 1.25= 343.75 feet 25 . 3.73 1.11 0.16 , <br /> s �: _ <br /> 4.Cak,ulate total friction loss by multiplying friction loss(C2) 35 6.96 2.06 0.3 <br /> by tt�e equivalent pipe length(C3)and divide by 100. �k =��'�`_,.., ', , . ' �' <br /> Friction Loss= 3.99 ff/100ft X 343.75 ft / 100= 13.7 feet 45 11.07 3.28 0.48 <br /> �� �.��� '-��` � _�.. <br /> D. Total head requirement is the sum of elevabon difference(A),special 55 4.76 0.7 <br /> head requirements(B),and total fiction Ioss(C4). � �,;� . � �.��'°� <br /> 25 R + 5 ft + 14.0 ft �{65 6.48 0.95 <br /> :t"��u.'9 :��_ s {6 }� 1 <br /> +� Y 4 � G <br /> Total Head: 44.0 feet <br /> 3. Pump Selection <br /> 1.A pump must be selected to deliver at least 50 gpm(1A or B) <br /> with at least 44.0 feet of total head(2D . <br /> I hereby certify that I have completed this work in accordance with all applicable ordinances,rules and laws. <br /> (signature) 810 (license#) 8/1/2006 Date <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.