Laserfiche WebLink
Quantities will include the following: Washed sand, 366 tons. The rock bed will require <br /> 35 tons of 11/2 clean binder rock, a Sandy Loam cap will require 134 tons of material, <br /> . and six inches of loamy topsoil to cover the mound azea will require 153 tons. <br /> The set-back for the well from the septic system area must be a minimum of 50 feet for <br /> both the septic tanks and the absorption area. The septic tanks will need to be at least 10 <br /> feet from the edge of the house and the absorption field must be 10 feet away from <br /> properiy lines. It's the responsibility of the owner to identify the properly boundaries for <br /> designing and installing the septic system. <br /> The septic system if properly insta.11ed and maintained should have no problems treating <br /> effluent in the matter that it was designed for. Nothiug other than human waste,toilet <br /> tissues, shower, sink,dishwasher and laundry water should be drained to the septic tanks <br /> and treatment field. If you have water treatrnent systems other than water softeners, in <br /> ex. Iron filters,they should be diverted from entering the septic system. <br /> Garbage disposals are not recommended, as they will add more solids to your septic tanks <br /> and may allow fine particles to enter the treatment area and clo�the system. Daily toiiet <br /> bowl cleaners, shower sprays(that are used after every shower), and excessive cleaning <br /> agents may kill bacteria needed to treat septic ei�luent. Additives are not needed,and are <br /> not recommended in properly maintained septic system. <br /> You should have your septic tanks pumped and inspected for proper maintenance <br /> by a certified pumper every 2 years. <br /> General � <br /> The soil conditions have been established at the test hole location only. There may be <br /> variations in soil stratigraphy between and azound the borin�s and interpolarion and <br /> extrapolation of the results is not warranted. <br /> References: <br /> MPCA Website: http://www.pca.state.mn.us/,�ro�rams/ists/index.html <br /> U of M Water Resources Center Website: http://septic.umn.edulindex.html <br /> If you should have any questions or need furkher information,you can conta.ct staff at the <br /> Loca1 Unit of Government that's permitting this project, and or me at your convenience. <br /> I hereby certify that I have completed this septic system design work in accordance with <br /> 's Rules and Standards Chapter 7080-81, local ordinances,rules and laws. <br /> Perne "Chip"Hentges Licenses#2064 <br />