Installer Summary <br /> 3000 gallon Septic tank(minimum) Multiple tanks or compartrr�ent req'd <br /> 1500 gallon Dose tank(minimum) at approximat,ely 31.00 gpi <br /> 41 GPM @ 19 ft. of head, Pump required <br /> 6.1 inch swing on Demand float <br /> 18 inches from bottom of tank to"pump ON"float <br /> 21 ir�hes from bottom of tank to"Hi Level Alarm"float <br /> �ft. of 2.0 inch supply tine with middle feed manifold connection <br /> 24 inch, or 2.00 ft. Sand Lift Mound <br /> 10 ft.wide by 75.0 ft. long Rock bed <br /> 6 laterals 2.00 inch diameter 36.5 ft. long 3.0 ft. lateral spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> YES Effluent fitter£t alarm <br /> 6 clean out&t vatve box assemblies <br /> 20.0 ft.Total sand ABSORPTION width (minimum) <br /> 6.0 ft. upslope and sideslope (sand beyond�ockbed) <br /> 10.0 ft. Downstope (sand beyond rockbed) <br /> BERM widths(topsoil beyond rockbed) using 4:1 slope ratio <br /> 12 ft� upslope berm <br /> 17 ft sideslope berms <br /> 23 ft. downslope berm opttonal 16 ft. downslope� 3:1 slope <br /> 4" inspection pipe <br /> 18" eover on top <br /> U slo e berm �2 23 <br /> DownsE e berm <br /> ` 12" cover on sides <br /> '--.�` (6"loamq cnp&6"topsoi� <br /> 2.00 ������ s�r�cl tift - �-•.�, <br /> 1.00 ��''` <br /> , , Depth to Lirniting '�''~- <br /> �lrilltlrl� �OrldltlOF? � —'-~ "'""'------ <br /> Absor tion Width �2c.�- _.--_____ _ __.,.--- _� _ _ <br /> Note: <br /> Fo� 4 to 1� sEopes, A.bso�ption l�dth is measured from the Bedequally in bath directians. <br /> For stapes >1%, Absorptlon Width is measured downhitl from the upslape ed�e of the Bed. <br /> Rock Bed: 25 yd'or"1.4= 35 ton <br /> Mound Sand: 262 Yd3 or•1.4a 366 ton <br /> Loamy Cap: 96 yd3 or'1.4= 134 ton <br /> Topsoil: �pg yd3 or'1.4� 153 ton <br />