2010-00808 - new septic
Orono
>
Property Files
>
Street Address
>
S
>
Salem Court
>
2055 Salem Court - 27-118-23-34-0008
>
Septic
>
2010-00808 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:21:25 PM
Creation date
8/1/2018 9:37:01 AM
Metadata
Fields
Template:
x Address Old
House Number
2055
Street Name
Salem
Street Type
Court
Address
2055 Salem Court
Document Type
Septic
PIN
2711823340008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mound Design Trov.Johnson(�co.Wriaht.mn.us <br /> for auestions or comments <br /> Property Owner: Jeff Soderstrom Date: 5/3/2010 <br /> Site Address: 2055 Salem Court, Orono 55356 PID: <br /> Comments: <br /> instructions: � =req'd input � �input or default � =calculated field *** =ir�staller info <br /> I) �6�bedroom Type � Residential System <br /> 2) ��GPD design flow <br /> s� No Garbage disposal or pumped to septic <br /> a> "** '. 30b0 :.Gallon septic tank(minimum) Mt�ktl�e ta�ks or compartmept req'd <br /> s) 1.2 GPD/ft�mound sand loading rate <br /> 6) 1'0 `ft rockbed width 75.0 ft rockbed length <br /> �> **' , 3.0 ft taterat spacing 3:p ft petforation spacing (default 3, range 2-3, for both) <br /> ►t�id�t�#e� "manifold connectlon <br /> _ . ,__ _ . <br /> s) *"•�laterals 36.5 feet tong 12 perfs/lateral 72 perfs total <br /> 9) *•" . 7f32 inch perts at �feet residual head gives 0.56 gpm flow rate pe�perforation <br /> (3/16"default) (2'head defautt) <br /> for this perf size St spacing, &pipe size on tine 12, max perfs/tateral- 30 , line#8 must be less--> OK <br /> io� �doses per day (5 recommended, 4 minimum) (4 wilt allow 2"laterals, 5 witl allow 1.5") <br /> �i> 180 gallons per dose (treatment volume) <br /> i2> 1.50 inch diameter taberals(or smaller)will meet"5x pipe volume" <br /> *•* 2.00 inch diameter laterals(or smaller) must be used to meet"4x pipe volume"requirement <br /> 2.00 inch diameter laterals (or smaller)will meet"3x pipe volume" <br /> is> �'�*�feet of 2.4 ;inch supply line leads to 10 gallons of drainback volume <br /> ("top feed"manifold to control the drainback} <br /> ia> 190 gallons TOTAL pump out volume(treatment+drainback) <br /> is> 10 feet vertical lift from pump to dispersat area, leads W a: <br /> i6> *** 41 GPM @ 19 feet of head, Pump requirement note: >50gpm may require an extra 3-6'of head <br /> »> •"* 1500 gal Dose tank(minimum) at approximately 31.�;gpi <br /> leads to a <br /> is� ••• 6.1 inch swing on Demand float, or timed dosing of 4.6 min ON (confirm pump rate with drawdown <br /> 4.7 hrs OFF test and adjust as necessary) <br /> i9> 12: ;inches of effluent from bottom of tank to cover pump <br /> Zo� **" 18 inches from bottom of tank to"pump ON"float <br /> zi> '•" 21 inches from bottom of tank to"Hi Level Alarm"float (Add a few more inches if Time Dosed) <br /> 2) C7gatlons reserve capacity (after High Level Alarm is activated) <br />