Laserfiche WebLink
-o��� � <br /> � . � <br /> ; o � <br /> o �. <br /> ,�, <br /> ��' � . CITY of ORON4 <br /> ,,..;,;:P.� <br /> � ,�,', : �`',• �► - <br /> � �!' e�r <,�;;; ,, �ti Municipal Offces <br /> � �� ,�f' ��tu�' G Street Address: q 5a'a�q'y b� � Mailing Address: <br /> �9kE8H�4'� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: <br /> �jss Sw�Cr� (d�( �' <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every iwo years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an inuninent threat to public health or safety. <br /> �3 J "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> �� or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing foc any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> � Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ��it ay �. <br /> Make sure septic tanks are pumped throuQh manhole and not throu¢h white inspection pipes. This ailows for the proper <br /> cleanins. Keea water softner and iron filter discharge out of septic svstem to prolons life of drainfield. Ask aumper to test <br /> alarm float to verifv alarm is still workine in vour house. T6e alarm warns owner that septaee is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINF�LD CONDITION(8-10): � <br /> � Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �������.�� 1�5 ��c��-pl,�,��- �— ��s�- be C�pl�c� <br /> �-1 �z=��--zo�v , <br /> �2�-0� C�u� <br /> Date of Inspection Matt Bolterman - Septic S��stem Inspector <br /> �ote: In the event that this inspection report is used tu satisfy the requirements for a mortgage or odier transfer of properh, be advised that this report does <br /> nut ��uarantee or c�rtih that an e�isting system ��•ill co�itinue to funclion properl�•. but is mereh' an opiniun of the adequac} of'the s�stem un�er cwrent <br /> cun�itiuns based on die availablc inlormation. <br />