Laserfiche WebLink
�O ��� . <br /> � . �' <br /> O O'��� <br /> �`�� � : � CITY of 4RON0 <br /> �'••ls.'�.')µ� � , . <br /> ��. � �'� / �'l�4 . <br /> „� ,� �, r; ,, ��C„ ,. Municipal Offices � <br /> �,t9 x ' t,g,�,G Street Address: �15a-a49-y6o � Mailing Address: <br /> kE8H0 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: <br /> �pa.p Sq�t h (ovrfi <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : 1 <br /> 1 "CODE SYSTEM" An ISTS which meeu all the location,design and construcdon standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTBM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an inuninent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS whicb may <br /> or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ti�= Z�`� ). <br /> Make sure seatic tanks are aumued throuQh manhole and not throush white inspection aiaes. This allows for the aroaer <br /> cleaning. Keep water softner and iron fiiter discharQe out of septic svstem to prolons life of drainfield. Ask aumaer to test <br /> alarm float to verifv alarm is still workine in vour house. T6e alarm warns owner that seata¢e is about to backua into basement. <br /> 7 Inspection risers missing-tanlcs could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: r^ �� �tJ \���� �� .. Q v�-� StP �-�� -�,,•.�C� S���{(� <br /> a--�a 5 ' <br /> �Z-�—o� ���..-- <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Not�: ln the event that this inspection report is used ro satisf) the requirements for a mortgage or uther transfer of propert�. be advised that this report does <br /> nu� �_u.uantee or certitj• that �ui existing system ��•ill continue to function properly. hut is mereh an opinion of the adequac} of the s�stem un�er currcnt <br /> �unditiuns based on the availablc inl�urmation. • <br />