My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: bldg/grading/buffer plans
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Drive
>
520 North Arm Drive - 06-117-23-31-0005
>
Correspondence
>
Re: bldg/grading/buffer plans
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:09 PM
Creation date
7/31/2018 12:37:37 PM
Metadata
Fields
Template:
x Address Old
House Number
520
Street Name
North Arm
Street Type
Drive
Address
520 North Arm Dr
Document Type
Correspondence
PIN
0611723310005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � 2335 Highway 36 W <br /> St.Paul,MN 55113 <br /> Tel 651-636-4600 <br /> Fax 651-636-1311 <br /> www.bonestroo.com <br /> �Bonestroo <br /> September 16, 2008 <br /> Ms. Evelyn Turner <br /> Planner <br /> City of Orono <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323 <br /> Re: 520 North Arm Drive <br /> File No. 000139-08000-2 <br /> File No. 2008-00142 <br /> Dear Evelyn; <br /> We have reviewed the grading plan for 520 North Arm Drive, dated 8-15-08. The plans proposed to remove <br /> an existing home and construct a new home with an attached garage. We have the following comments <br /> with regards to engineering matters: <br /> • The survey should show the existing home and garage, if they are still standing. <br /> • Existing contours should be provided for the entire lot, including over the driveway. Contours <br /> should extend at least 50' beyond all property lines. <br /> • All proposed grading should be shown on the survey. It appears all contours currently shown are <br /> existing. <br /> • Detailed and engineered retaining wall design and details should be submitted for all retaining <br /> walls over 4' in height. This would apply to the proposed wall to the north of the garage, <br /> • All trees to be removed should be labeled. <br /> • A detail for silt fence with steel T-posts should be shown on the plans. <br /> • There are two manholes shown to the south of the garage, More information is needed for these <br /> manholes, including what type of manholes they are, inverts, type, size, and direction of any pipe <br /> connected to the manholes. <br /> • lohn Smyth has reviewed and submitted comments on this application regarding wetland buffer <br /> requirements. His memo dated 9-11-08 is attached, <br />
The URL can be used to link to this page
Your browser does not support the video tag.