Laserfiche WebLink
__ _ ._ ..__. _ ----.....______ _ _ _ _ _ _ <br /> Golden VaR y,MNC55427A3700 ad Calculations Elite 3oftware D Custom RPa el 1 I <br /> ., _ <br /> � <br /> Pro�ect Report � <br /> _ _ .. <br /> ....._.__. <br /> ' Genera( Project fnformation � : <br /> Project Filename: S:\FHDATAIPROJECTS\RANDYIbackesoronorambler.rhv <br /> Project Titie: Custom Rambler ' <br /> Designed By: Randy <br /> Project Date: 8-12-05 , <br /> Project Comment: ! <br /> Client Name: Backes Companies, Inc. <br /> Client Address: 7026 Brooklyn Blvd. <br /> Client City: Brooklyn Center, Minnesota 55429 <br /> Client Phone: 763-566-1524 ' <br /> Client Fax: 763-566-1525 � <br /> Company Name: Flare Heating &Air conditioning, Inc. � <br /> Company Representative: Randy � <br /> Company Address: 9303 Plymouth Ave. N. ' <br /> Cornpany City: Golden Valley, Minnesota 55427 ! <br /> Company Phone: 763-542-1166 <br /> Company Fax: 763-542-3101 <br /> Company E-Mail Address: rimker@flareheating.com <br /> Company Website: flareheating.com <br /> Company Cornment: You Can Feel The Difference <br /> _ <br /> Design Data : ' _ . .. _,_.. _ .__ I <br /> _ _ _ <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 � <br /> Elevation Heating Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> � <br /> Drv Bulb Wet Bulb Rel.Hum Drv Bulb Difference ' <br /> Winter: -20 0 0 72 0 <br /> Surnmer: 95 75 50 75 36 <br /> _ .. __ _ , <br /> i Check Figures � <br /> _ .___ i <br /> Total Building Supply CFM: 2,367 CFM Per Square ft.: 0.316 <br /> Square ft. of Room Area: 7,478 Square ft. Per Ton: 1,495.567 <br /> Building Loads . , _ . . 1 <br /> Total Heating Required With Outside Air: 152,740 Btuh 152.740 MBH <br /> Total Sensible Gain: 47,938 Btuh 80 % <br /> Total Latent Gain: 12,063 Btuh 20 % <br /> Total Cooling Required With Outside Air: 60,001 Btuh 5.000 Tons (Based On Sensible+ Latent) <br /> 5.693 Tons(Based On 75% Sensible Capacity) <br /> Notes _ _ . , <br /> � <br /> � <br /> _ ;: � <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> ; All computed results are estimates as building use and weather may vary. <br /> ' Be sure to select a unit that meets both sensible and latent loads. <br /> S:\FHDATAIPROJECTS\RANDYIbackesoronorambler.rhv Friday, August 12, 2005, 1:02 PM <br />