Laserfiche WebLink
' ❑ Case Window:Wood Frame,2 Pane w/Low-E,U-factor:0.330 <br /> ' . For windows without labeled U-factors,describe features: <br /> ' ' #Panes—Frame Type Thermal Break? Yes—No <br /> Comments: <br /> ❑ Bath DH Window:Wood Frame,2 Pane w/Low-E,U-factor:0.330 <br /> For windows without labeled U-factors,describe features: <br /> #Panes Frame Type Themtel Breek?_Yes No <br /> Comments: <br /> ❑ Bath Arch Window:Wood Frame,2 Pane w/Low-E,U-factor:0.330 <br /> For windows without labeled U-factors,describe features: <br /> #Panes Frame Type 7riermal Breek? Yes No <br /> Comments: <br /> ❑ Closet Window:Wood Frame,2 Pane w/Low-E,U-fador:0.330 <br /> For windows without labeled U-factws,describe features: <br /> #Pan�—Frame Type Thermal Break? Yes No <br /> Comments: <br /> ❑ Windows:Wood Frame,2 Pane w/Low-E,U-factor:0.330 <br /> For windows without labeled U-factors,desrxibe features: <br /> #Panaa Frar�Type Thermel Break? Yes No <br /> Comments: <br /> ❑ Arch Window:Metal,Thermal Break,2 Pane w/Low-E,U-factor:0.330 <br /> For windows without labeled U-factors,describe features: <br /> #Panes Frame Type Thertnal Break?_Yes No <br /> Comments: <br /> ❑ Rear Window:Wood Frame,2 Pane w/Low-E,U-factor.0.330 <br /> For windows without labeled U-tactors,describe features: <br /> #Panes Frame Type Therrnal Break?—Yes No <br /> Comments: <br /> Note:Up to 15 sq.ft.of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements. <br /> Doors: <br /> ❑ Sliding Door:Glass,U-factor:0.330 <br /> Comments: <br /> ❑ Door:Solid,U-factor:0.150 <br /> Comments: <br /> ❑ OH Door:Solid,U-factor:0.057 <br /> Comments: <br /> Floors: <br /> ❑ Garage Floor:Heated Slab-On-Grade,R-0(uninsulated) <br /> Comments: <br /> ❑ Floor:All-Wood JoistlTruss Over Uncond.Space,R-38.0 c�ntinuous insulation <br /> Comments: <br /> Floor insulation is installed in pertnanent contact wiMi the underside of the subfloor decking. <br /> Air Leakage: <br /> � Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. <br /> � Recessed lights are either 1)Type IC rated with enclosures sealed/gasketed against leaks to ttie ceilirg,or 2)Type IC rated and ASTM <br /> E283 labeled,or 3)installed inside an air-tight assemWy witl►a 0.5"dearance from combustibie materials and a 3"dearance irom <br /> insulation. <br /> Vapor Retarder: <br /> � Vapor retarder is installed on the wamrin-winter side of all non-vented framed ceilings,walis,and floors;or it has been determined that <br /> moisWre or its freezing will not damage the materials;or other approved means to avoid condensation are provided. <br /> Project Title:Kaczke Addition Report date: 12/15N 1 <br /> Data filename: Page 4 of 5 <br />