My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including future site info
Orono
>
Property Files
>
Street Address
>
D
>
Deer Run Trail
>
2900 Deer Run Trail - 04-117-23-24-0021
>
Septic
>
septic info including future site info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:12:02 PM
Creation date
7/30/2018 10:54:06 AM
Metadata
Fields
Template:
x Address Old
Address
2900 Deer Run Tr
Document Type
Septic
PIN
0411723240021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� O� <br /> O :., O <br /> �`�y���� CITY of ORONO <br /> , �... �. <br /> , ,, <br /> ��1� � ��� <br /> �� �`�i���'�; �:i�'�� G,ti,ti Muntc�pal Offices <br /> I�;�;��r ;;�4� Street Address: Maliln�Addreu: <br /> � � 2750 Kelle Par1cwa <br /> �H r Y P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �e��- `' v�-�^��q� Address: a�t ob <br /> Oee� R�� �r. <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. <br /> The on-site sewage treatment system at the above address has been inspecced and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-�: � <br /> �1 "CODE SYSTEM" tln ISTS which meets a11 the locatioq design and constructioa standards of the cuaent Orono Muaicipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the locatio�design and construction standards ofihe currr.nt prono Municipal <br /> Code but does meet the three foot separation requiremerrt,and which is not failing or an immineiR threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz IIood plain,any ISTS which may <br /> or may not meet all the locatioq design,or constcuction standardy of the currurt Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than thcee feet of unsaturated soil or sand betwern the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-10): S <br /> Tank inspection indicates: <br /> QPumpout not naeded at this time. <br /> 6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 yeazs. Tank was last pumped � �� ), <br /> 7 Solidc accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. <br /> 8 Sy�stam is discharging W the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection riseis missing-tanks could not be inspected Inspection risas(4"dia.pipe)must be installed in each tanlc at next pumpout If tanks <br /> have not been pumpad out within the last three yeacs,they should be pumped out now. <br /> 10 Inspection pipe is locatad direetly over taiilc ba@le(doa not give ucurata measurement of solids aecumulation). If tanks have not been pumped <br /> out within the lact three years,thay should be pumped out now. <br /> DRAINFIELD CONDITION 11-1� : l� <br /> 1 Drainfield'u dry,no surfacing evideat <br /> 12 Some avidrnce of surfacing,not critical yet <br /> 13 Draintield is saturated and visibly discharging artreatzd effluecrt to the surfaca Coruad the City Inspector immediately.Repairs must be <br /> compltted withiit 90 days. <br /> 1� Draintield estrnt and wndition uaknown. <br /> CO1vIl�fENTS: 5�Sfi e M l o o k5 p (� <br /> 6-s-- o � �� r <br /> f <br /> Date of Inspection Septic System Inspeetor � <br /> Note: In the evrnt that thi�ie�spection report is used to satisfy the requiremaAs for a moctgage or otha transfa of property,be advised that this report does not guarantee <br /> or certify that an e�dsting system will continue to function ptoperly,but is maely aa opinion of the adequacy of the system under cuireac conditions baved on the availabte <br /> information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.