My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/structural specs for addition
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/structural specs for addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:33:21 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DIV�SION 1: GENERAL REQUIREMENTS <br /> Q1010 SUMMARY OF THE WORK <br /> General: <br /> The work of the contract consists,in general,of the construction,of an addition at the Richard and Britt <br /> Gage residence,Long Lake,Minnesota as shown on the Drawings and described in these Specifications. <br /> It includes both the removal of materials and the installation of new materials. The Owner has the right <br /> to rejects a11 bids.If the Owner accepts a bid,the successful Bidder/Builder will enter into an ag�ment <br /> with the Owner to undertake this project <br /> The General construction contraet includes the contracts,the drawings and the project manual.The <br /> Mechanical and Electrical work shall be bid under separate contracts. <br /> The data set forth in this specification and indicated on the drawings is accurate as can be obtained,but <br /> its extreme accuracy can not be guaranteed. Final application shall be determined by the approval of the <br /> Owner. <br /> The law and location of the construction sites govern the construction of any contract,all building, <br /> heatitig,ventilating,plumbing and electrical codes of the State of Minnesota and local laws and <br /> ordinances,which are hereby made part of each Contract. <br /> Scope of Work; Contractors will provide material delivered to the site and all labor to complete the work <br /> according to the drawings and the project manual. All Sub-Contractors shall be responsible to the <br /> General eontractor. The Owner will enter into various Contracts as required to complete the work <br /> described. <br /> Ther�e shall be no commanication,concernin tec6nical matters,between the Owner and th� <br /> Contractors regardiag the Work xfter it t�us. All commnmication regarding snch matters shall <br /> take place between the Contractors and the Architect and or his Engineers. <br /> 01015 GENERAL STRUCTURAL NOTES <br /> Design Unit$tresses <br /> • Structural Steel-ATSM A572"W shapes;ASTIVi A36 for angles,plates saddles and bars. <br /> • Structural Tube Steel-ATSM A501,Cnrade B. <br /> • Reinforcin�St�l-ATSM A615,Grade 60. <br /> • Weld�Wire Fabric-ATSM A185. <br /> • Concrete-fc=30(�psi @.2a days,footing,slabs and beau►s;except 4000psi with 7%air <br /> entrainment for garage slab. <br /> • Masonry-f'a1= 1500 psi. <br /> • Concrete eore fill for masonry-3000 psi @.28 days. <br /> • Microlam beams and PSL cols-Tivss Joist MacMillan 2.OE,Fb=2900 psi treated when exterior <br /> use. <br /> • Glulam beams-DFL,Fb=2400 psi with exterior glue lines. <br /> • Dimensional lumber SPF#2 or better,treated for exterior use. <br /> Design Live Load$ <br /> • Roof Live Load-40 psf. <br /> • Floor Live Load-40 psf. <br /> • Balconies and Decks-64 psf. <br /> � Wind Load- 15 psf. <br /> Foundat�oas <br /> • Footings are designed for an asswned maximum soil bearing pressure of 20QOPSF. It shall be the <br /> responsibility of the contractor to verify that this value is achieved at the foo�ing elevations <br /> indicated and without long term damaging differential settlement to the structure. <br /> • Backfill material against the fopndation walls sha11 be granular,free draining and contain not more <br /> than l OP/o passing#200 sieve <br /> • Miniunum soil cover for new exterior footings at buiIding perimeter shall be not less than 3'-6" <br /> unless required by local building code tb be deeper or where required to match existing footing <br /> cover. Soil cover for footings supporting attached exterior d�cks shall be 5'-0". <br /> • Unless otherwise noted,footings under exterior and interior bearing wa.11s shall be 12"wider than <br />
The URL can be used to link to this page
Your browser does not support the video tag.