My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/structural specs for addition
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/structural specs for addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:33:21 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Available Products: Subject to compliance with <br /> 2.4 RELATED MATERIALS <br /> 1. Available Manufacturers: Subject to compliance with requirements. <br /> A. Sand Cushion: Clean,natural sand. <br /> B. Vapor Retarder: Provide vapor retarder that is resistant to deterioration when tested <br /> according to ASTM E 154,as follows: <br /> 1. Polyethylene sheet not less than 8 mils thick. <br /> C. Liquid Membrane-Forming Curing Compound: Liquid-type membrane-forming curing <br /> compound complying with ASTM C 309,Type I, Class A. Moisture loss not more than 0.55 kg/sq. meter <br /> when applied at 200 sq.ft./gal. <br /> 1. Provide material that has a maximum volatile organic compound(VOC)rating of 350 mg per <br /> liter. <br /> 2. Available Products: Subject to compliance with requirements. <br /> PROPORTIONING AND DESIGNING NIIXES <br /> See)1015 General Structural <br /> 2.5 CONCRETE MII�LING , <br /> A. Ready-Muced Concrete: Comply with requirements of ASTM C 94,and as spec�ed. <br /> PART 3-EXECUTION <br /> " 3.1 GENERAL <br /> A. Coordinate the installation of joint materials,vapor retarder/barrier,and other related materials with <br /> placement of forms and reinforcing steel. <br /> 3.2 FORMS <br /> A. General: Design,erect,support,brace,and maintain formwork to support vertical,lateral, <br /> static,and dynamic loads that might be applied until concrete structure can support such loads. Construct <br /> formwork so concrete members and structures aze of correct size,shape,alignment,elevation,and position. <br /> Maintain formwork construction tolerances and surface inegularities complying with the following ACI 347 <br /> limits: <br /> 1. Provide Class A tolerances for concrete surfaces exposed to view. <br /> 2. Provide Class C tolerances for other concrete surfaces. <br /> B. Provisions for Other Trades: Provide openings in concrete formwork to accommodate <br /> work of other trades. Determine size and location of openings,recesses,and chases from trades providing <br /> such items. Accurately place and securely support items built into forms. <br /> 33 VAPOR RETARDER/BARRIER INSTALLATION <br /> A. General: Place vapor retarder/barrier sheeting in position with longest dimension parallel <br /> with direction of pour. <br /> B. Lap joints 6 inches and seal with manufacturer's recommended mastic or pressure- <br /> sensitive tape. <br /> 3.4 PLACING REINFORCEMENT <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.