My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/structural specs for addition
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/structural specs for addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:33:21 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GYPSUM DRYWALL <br /> SECTION 09250 <br /> PART 1 -GENERAL <br /> 1.1 SCOPE <br /> A. Drawings and general provisions of Contract,including General and Supplementary Conditions <br /> and Division 1 Specification Sections,apply to this Section. <br /> l. Insulation is specified in Division 7 Section 07210"Insulation". <br /> B. All Gypsum Drywall: on walls and ceilings,to the extent shown on drawings. <br /> C. Gypsum Board:Regular wallboard fire-rated wallboard,water resistant wallboard;backer board, <br /> acoustical insulation. <br /> D. Work is to be one layer and two layer gypsum board,type and thickness as shown on drawings. <br /> All walls and the ceiling in Garage that face habitable rooms shall have 2layers of 5/8"type x fire rated. <br /> No other walls shall be faced with fire-rated material. Finishing of joints and heads of fastening devices. <br /> Caulking as required by manufacture and according to good practice. <br /> E. Anchors,adhesives,hangers,clips,furring channels,accessories,etc.,(unless specified under <br /> other sections)as required to adequately support and secure work in place,starting from conditions of <br /> building structure. <br /> PART 2-MATERIALS <br /> 2.1 GENERAL: ALL MATERIALS SHALL COMPLY WITH ANSI-A97.1. <br /> A. Manufacturer:Unless otherwise specified,excluding metal studs and textured spraying of <br /> ceilings,provide all materials as the product of one manufacture with installation,and erection in strict <br /> accordance with manufacturer's directions. Provide materials of U.S.Gypsum,National Gypsum or <br /> Gold Bond. <br /> B. Dalivery and Storage:Materials to be delivered in original unopened containers and bundles, <br /> with manufacturer's hallmark,stored to protect from the elements and damage. <br /> 2.2 GYPSUM MATERIALS AND ACCESSORIES <br /> A. Gypsum Board:Products of U.S.Gypsum,National Gypsum Company and Georgia Pacific, <br /> 5/8"thick,48"wide,unless otherwise noted. Lengths as required to minimize end joints. Fire rated <br /> g,ypsum board:USG sheetrock firecode wallboard; 5/8"ti�ick,48"wide,tapered edge; lengths as required <br /> to minimize end joints. <br /> 1. Water-resistant gypsum board:USG sheetrock w/R Gypsum wallboard;5/8"thick,48" <br /> wide,tapered edge; lengths as required to minimize end joints.Note: All walls in Master <br /> Bathroom and in Washer-Dryer Closet shail have this type of gypsum board. <br /> 2. Gypsum b,acking board:USG Baxbord,ffiickness if called for on drawings,48"wide <br /> square edges; lengths as required to minimize end joints. <br /> B. Fastenings:As recommended by manufacturer, lengti�s as required,use screw types"S"screws. <br /> Comply with requirements U.S. label service. <br /> C. Adhesives:As recommended byGypsum Board manufacturer,for adhesively applying gypsum <br /> board to concrete block and insulation,for laminating in multi=layer and single layer at fire rated <br /> construction. <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.