My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/structural specs for addition
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/structural specs for addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:33:21 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCESS PANELS <br /> SECTION 08305 <br /> PART 1-GENERAL <br /> 1.1 RELATED DOCUMENTS <br /> A. Drawings and general provisions of the Contract, including General and Supplementary <br /> Conditions and Division 1 Specification Sections,apply to this Section. <br /> 1.2 SUNIlIZARY <br /> A. This Section includes the following types of access doors: <br /> 1. Wall access doors. <br /> 2. Fire-rated wall access doors. <br /> 3. Ceiling access doors. <br /> B. Related Sections: The following Sections contain requirements that relate to this Section: <br /> 1. Division 9 Section"Gypsum Board Assemblies" for gypsum boazd walls and ceilings. <br /> 2. Division 9 Section"Tile"for ceramic tile walls. <br /> 3. Division 15 Section"Duct Accessories"for duct access doors. <br /> 1.3 5UBMITTALS <br /> A. General: Submit each item in this Article according to the Conditions of Contract and Division 1 <br /> Specification Sections. <br /> B. Product data for each type of access door assembly specified,including details of construction <br /> relative to materials, individual components,profiles, fmishes,and fire-protection ratings(if required). <br /> 1. Include complete schedule,including types,general locations,sizes,wall and <br /> ceiling construction details,latching or locking provisions,and other data <br /> pertinent to installation. <br /> 1.4 QUALTTY ASSURANCE <br /> A. Single-Source Responsibility: Obtain access doors for entire Project from one source and by a <br /> single manufacturer. <br /> B. Fire-Rated Door Assemblies: Units that comply with NFPA 80,are identical to door and <br /> frame assemblies tested for fir�test-response characteristics per test method as indicated below,and are <br /> labeled and listed by UL,Warnock Hersey,or another testing and inspecting agency acceptable to <br /> authorities having jurisdiction. <br /> � 1. Test Method for Vertical Installations: ASTM E 152. <br /> 2. Test Method for Horizontal Installations: ASTM E 119. <br /> C. Size Variations: Obtain Architect's acceptance of manufacturer's standard size units,which may <br /> vary slightly from sizes indicated. <br /> 1.5 COORDINATION <br /> A. Verification: Determine specific locations and sizes fo�access doors needed to gain access to <br /> concealed equipment,and indicate on schedule specified under'"Submittals"Article. <br /> . * <br /> PART 2-PRODUCTS � <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.