My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/Structural specs for cabana,pool,hot tub areas
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/Structural specs for cabana,pool,hot tub areas
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:15:05 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' <br /> � WOOD WINDOWS <br /> SECTION 08610 <br /> ITHIS SECTION USES THE TERM"ARCHITECT." <br /> , P.ART 1 -GENERAI., <br /> 1.1 RELATED DOCUMENTS <br /> ' A. Drawings and general provisions of Contrac,�, including General and Supplementary <br /> Conditions and Divisional Specification Sections,appiy to this section. <br /> ' 1.2 SUNIlI�ARY <br /> A.This Section includes the following vinyl-clad wood window types incl�ding glazing: <br /> ' 1. Non-aperative(Fixed)Window Units. <br /> B. Related Sections: The following secrions contain requirements that relate to this section: <br /> ' 1. Join#sealingbetween wood windows and adjacent materials is specified in Division <br /> 7 Section"Joirit Seaiers." <br /> 2. Trim for wood windows,aze specified in Division d"Finish Carpentry" <br /> ' 3 Owner shali furnish windows and Generai Contractor wili install. <br /> 1.3 SYSTEM PERFORMANCE REQUIREMENTS <br /> ' A. Standards: Performance requirements for structural performance,air infilfration,and water <br /> penetration for wood windows are those specified in NWWDAfaI.S.a2"Indushy Standard <br /> for Wood Window Units." <br /> ' B. Performance Requuements(Grade 40 Windows): Each required window unit shall comply <br /> with the following performance requirements: <br /> ' 1. Air Infiltration: Not rnore than 0.25 cfm per sq. ft. of overall frame area at an <br /> inward test pressure af 1.57 lbf per sq.ft. <br /> 2. Water Penetration: No water penetration as defined in the test method at an inward <br /> ' test pressure of 4.43 lbf per sq.ft. � <br /> 3. Structural Performance: No glass breakage, damage to hardware, permanent <br /> deformxtion that would impair operation of#he unit,or residual deflection greater <br /> ' #han 0.4 percent of the span at a positive (inward) aud negative {ouh�vard) test <br /> pressure of 40�1bf per sq.ft. <br /> 4. Forced Entry Resistance: Provide window units that comply with requirements for <br /> ' Performance Level 10 when tested in accordance with ASTMaFa588. <br /> 1.4 SUBMITTALS <br /> ' A. General: Submit the foltowing in accordance with Conditions of the Contract and <br /> Divisional Specification Sections: <br /> , 1. Product data for each type of wood window required,includin� <br /> a. Standazd construction details and fabrication methods. <br /> b. Profiles and dimensions of individual components. <br /> ' c. Daxa on finishes. <br /> WOOD WINDUWS 'Page I of 5 <br /> ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.