My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/Structural specs for cabana,pool,hot tub areas
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/Structural specs for cabana,pool,hot tub areas
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:15:05 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> IGYPSUM DRYWALL <br /> SECTION 0925Q <br /> � PART1 -GENERAL <br /> � 1.1 SCOPE <br /> A. Drawings and general provisions of Contract, including General and Supplementary <br /> Conditions and Division 1 Spec�cation Sections,apply to this Section. <br /> �� <br /> 1. Insulation is specified in Division 7 Section 07210"Insulation". <br /> � B. Aii Gypsum Drywall: on walls and the ceiling in the storage and ec{uipment room,to the <br /> extent shown on drawings. <br /> C. Gypsum Board: Regular wallboard fire-rated wallboard,water resistant wallboard;backer <br /> � board, <br /> acoustical insulation. <br /> � D. Work is to be one Iayer gypsum board,type and thickness as shawn on drawings. Finishing <br /> of joints and heads ofr fastening devices. Caulking as required by manufacture and <br /> according to good practice. <br /> � E. Anchors, adhesives, hangers, clips, furring channeIs, accessories, etc.,(unless specified <br /> under ofher <br /> sections} as required to adequately support and secure work in place, starting from <br /> � condi#ions of building structure. <br /> F. Insulation <br /> � PART 2-MATERIALS <br /> 2.1 GENERAL:ALL MA,TERIALS SHALL COMPLY WITH ANSI-A97.1. <br /> � A. Manufacturer: Unless otherwise specified, provide ail materials as the product of one <br /> manufacture with installation, and erection in strict accordance with manufacturer's <br /> directions. Provide materials of U.S. Gypsum,National Gypsum or Gold Band. <br /> � B. Delivery and Storage: Materials to be delivered in originai unopened containers and <br /> bundles,with <br /> , manufacturer's hallmark,stored to protect from the elements and damage. <br /> 2.2 GYPSUM MATERIALS AND ACCESSORIES <br /> � A. Gypsum Board:Products of U.S.Gypsum,National Gypsnm Company and Georgia Pacific, <br /> 5/8" <br /> thick,48°wide,un�less otherwise noted. Lengths as required to minimize end joints. <br /> � B Fastenings: As recommended by manufacturer, leng�ths as required, use screw types"S" <br /> screws. <br /> Comply with requirements U.S.label service. <br /> � <br /> GYPSUM DRYWALL Page 1 of 3 <br /> � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.