Laserfiche WebLink
�I F O R T E MEMBER REPORT Basement, WindowHeaderin GreatRoom PASSED <br /> 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 <br /> Overall Length:4'4 1/2" <br /> G 1 1 0 <br /> 4. <br /> 0 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results nctua���ocatioo anowea reesuit LDF Load:Combinadon(Pattem} System:Wall <br /> Member Reaction(Ibs) 3630 @ 4'3" 3825(3.00") Passed(95%) -- 1.0 D+ 1.0 L(All Spans) Member Type:Header <br /> Shear(Ibs) 76 @ 10 3/4" 2498 Passed(3%) 1.00 1.0 D+ 1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-Ibs) 140 @ 2'1 1/2" 3431 Passed(4%) 1.00 1.0 D+ 1.0 L(All Spans) Building Code:IBC <br /> Live Load DeFl.(in) 0.001 @ 2'1 1/2" 0.142 Passed(L/999+) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> !Total Load DeFl.(in) 0.002 @ 2'1 1/2" 0.213 Passed(L/999+) -- 1.0 D+1.0 L(All Spans) <br /> — -- --- — ___ <br /> • DeFlection criteria:LL(L/360)and TL(L/240). <br /> • Bracing(Lu):All compression edges(top and bottom)must be braced at 4'4 1/2"o/c unless detailed otherwise.Proper attachment and posidoning of lateral <br /> bracing is required to achieve member stability. <br /> •Applicable calculations are based on NDS 2005 methodology. <br /> Bearing Loads to Supports(Ibs) <br /> Supports Total Available Required Dead F�O°� Total Accessories <br /> ���e <br /> �, 1-Tnmmer-SPF 1.50" 1.50" L50" 782 1025 1807 None ''. <br /> 2-Trimmer-SPF 3.00" 3.00" 2.85" 1487 2143 3630 None <br /> ''�.. TribuWry Dead Floor Live <br /> Loads �o�r;o� Width �o.vo� �i.00� Commentr <br /> I 1-Uniform(PSF) 0 to 4'4 1/2" 1' 15.0 40.0 Residential-Living Areas <br /> �,2-Point pb) 0 N/A 735 940 �' <br /> �'�3-Point(Ib) 4'4" N/A 1437 2053 � <br /> Weyerhaeuser Notes ���„od:�-a$,-�� <br /> '�,Weyerhaeuser warrantr that the sizing of itr produds will be in acmrdance with Weyerhaeuser product design criteria and published design values. <br /> �Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authoriry having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> '�. Forte Software Operator dob Notes 8i 16/2013 10:08:12 AM <br /> ��stm sPre�tier Gonyea Homes Forte v4.1,Design Engine:V5.7.0245 <br /> �yman 2325 Glendale Cove Lane GH0402(2325 Glendale Cove Ln.).4te <br /> ! (952)470-4817 Orono, MN <br /> ; justin_spreitzer@tymanlumber.com Hoehn Resid. Page 4 Of 17 <br />