Laserfiche WebLink
On the North Shore of ' <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> � . � � 1335 S. Brown Rd. <br /> Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER �,.�5 �• J�-nU mQGh�� ADDRESS .� ��n'� dQ� <br /> PERMIT NO.'S. DATES CONTRACTORS <br /> City Ordinance No. 210 requires thet each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage <br /> treatment system at the above address has been inspected and appears to fall into the category checked below. <br /> (This is �an existing system ❑ new construction) <br /> � � Meets or exceeds current City atandards in ail respects relating to design,construction,and location.Appears to be operating <br /> •properly. <br /> �2 Does not meet all current City standards for new construction (1978 Code► but in most respects appears to be designed, <br /> located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet currerit City standards for design,construction or location, but is failing to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise ereating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soif testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a�rmit before work is started. <br /> SYSTEM CONDITION (m .Checked items may require your action) <br /> Tank inspection indicates: ❑ Inspsction pipe is located directly over tank baffle.(Dces not <br /> �Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks <br /> ❑ Solids aecumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: I <br /> should be pumped out es soon as possible. � Orainfield is dry,no surfacing eviden�nP(a25�,t,rnP�a�R.� <br /> ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not criti I yet. <br /> within 48 hours to etiminate surface discharge. O Drainfield is satureted and visibly discharging untreated <br /> ❑ Inspection ri�rs missing—tanks could not be inspected, effluent to the surface. This condition may require replace• <br /> Inspection risers (4"dia. pipe)must be installed in esch tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water � Future Expansion <br /> ❑ Soil table,and system condition) f�Adzquate <br /> O High water table �71 Low ❑ Fair <br /> � Lot size �Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surfece discharge. <br /> COMMENTS: <br /> 1"���� <br /> Date of Inspection Septic e ns ector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised.that <br /> this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinio�of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />