Laserfiche WebLink
t <br /> � <br /> THE 2007 MINNESOTA STATE BUILDING CODE <br /> other equipment, the installation of which is wall, unless supporting a surcharge or <br /> regulated by the code; or cause any such work impounding Class I, II, or III-A liquids; <br /> to be done, shall first make appiication to the <br /> building official and obtain the required (5) water tanks supported directly <br /> permit. upon grade if the capacity does not exceed <br /> 5,000 gallons (18,927 L} and the ratio of <br /> Subp. 2. Anoual permit. In Iieu of an height to diameter or width does not exceed 2 <br /> individual permit for each alteration to an to 1; <br /> already approved electrical, gas, mechanical, <br /> or plumbing installation, the building official (6) sidewalks and driveways that are <br /> may issue an annual permit upon application not part of an accessible route; <br /> for the permit to any person, firm, or <br /> corporation regularly employing one or more (7) decks and platforms not more�than <br /> qualified trade persons in the building, 30 inches (762 mm) above adjacent grade and <br /> structure, or on the premises owned or not attached to a structure with frost footings <br /> operated by the applicant for the perniit. and which is not pact of an accessible route; <br /> Subp. 3. Annual permit records. The (8) painting, papering, tiling, <br /> person to whom an annuai permit is issued carpeting, cabinets, countertops, and similaz <br /> shall keep a detailed record of alterations finish work; <br /> made under the annual permit. The building <br /> o�cial shall have access to the records at all (9) temporary motion picture, <br /> times or the records shall be filed with the television,and theater stage sets and scenery; <br /> building official as designated. <br /> (10)prefabricated swimming pools <br /> Subp. 4. Work egempt from permit. installed entirely above ground accessory to <br /> Exemptions from permit requirements of the dwelling units constructed to the provisions of <br /> code do not authorize work to be done in any the International Residential Code or R 3 <br /> manner in violation of the code or any other occupancies constructed to the provisions of <br /> laws or ordinances of this jurisdiction. the International Building Code, which do not <br /> Permits shall nat be required for the exceed both 5,000 gallons in capacity (l 8,925 <br /> following: , L)and a 24 inch(610 mm)depth; <br /> A. Building: (11) window awnings supported by an <br /> exterior wall that do not project more than 54 <br /> (1} one-story detached accessory inches (1,372 mm) from the exterior wall and <br /> structures, used as tool and storage sheds, do not requ�re additional support, when <br /> playhouses, and similar uses, provided the constructed under the International <br /> floor area does not exceed 120 square feet Residential Code or Group R 3 and Group U <br /> (11.15 mm2); occupancies constructed to the provisions of <br /> tl�e International Building Code; <br /> (2) fences not over six feet (1,829 <br /> mm)high; (12)movable cases, counters, and <br /> (3) oil derricks; partitions not over five feet, nine inches <br /> (1,753 mm) in height; <br /> (4) retaining walls that are not over <br /> four feet(1,219 mm} in height measured from <br /> the bottom of the footing to the top of the , <br /> 135 <br /> , , <br />