Laserfiche WebLink
ADMINlSTRATION <br /> S�CTION R1 Q5 4. Steam,hot or chilled water piping within any heatin�or <br /> PERMlTS coolin� equipment re�ulated by this code. <br /> R1Q�.1 Required.Any owner or authorized a�ent who intends 5. Replacement of any minor part that does not alter <br /> to consvuct, enlarge, alter, repair, move, demolish or chanoe approva]of equipment ormake s�ch equipmentunsafe. <br /> the occupancy of a buildin; or structure. or to�erect, install, 6 portable evaporative coolers. <br /> enlar�e,alter.repair.remove,convert or replace any electrical, <br /> Qas,mechanical or plumbinR svstem. the installation of which 7. Self-contained refri�eration systems containing 10 <br /> is re�ulated b}�this code,or to cause an}�such work to be done, pounds(4.54 kg)or less of refritrerant or that are actuated <br /> shall first make application to the building officia] and obtain by motors of l horsepower(746 W)or less. <br /> the required permit. 8. portable-fuel-cel] appliances that are not connected to a <br /> R1R�.� V�%ork exempt from permit. Perniits shal] not be fixed pipin� system and are not interconnected to a <br /> required for the followinD. Exemption from permit require- power arid. <br /> ments of this code shall not be deemed to arant authorization The stopping of leaks in drains,water,soil,waste or vent pipe; <br /> for any work to be done in any manner in violation of the provi- Provided,however,that if any concealed trap,drainpipe,water, <br /> sions of this code or any other laws or ordinances of this soi1,waste or vent pipe hecomes defective and it becomes nec- <br /> jurisdiction. essary to remove and replace the same with new material,such <br /> Buildine: work shall be considered as new work and a permit shall be <br /> 1. One-story detached accessory structures used as tool and obtained and inspection made as provided in this code. <br /> stora�e sheds,playhouses and similar uses,provided the The clearing of stoppa�es or the repainng of lealcs in pipes, <br /> floor area does not exceed 120 square feet(11.15 m�). ��ves or fixtures, and the removal and reinstallation of water <br /> 2. Fences not over 6 feet(1�?9 mm)high. closets, provided such repairs do not involve or require the <br /> 3. Retainin� walls that are not over 4 feet (2219 mm) in replacement or rearrangement of valves,pipes or fixtures. <br /> hei�ht measured from the bottom of the footin�to the top R105.?1 Emergency repairs. Where equipment replace- <br /> of the wall, unless supporting a surcharge. ments and repairs must be performed in an emergenc}�situa- <br /> 4. W ater tanks supported directly uPon grade if the capacity tion, the pernut application shall be submitted within the. <br /> does not exceed 5,000�allons(18 927 L)and the ratio of next workina business day to the buildin�official. <br /> height to diameter or width does not exceed 2 to 1. �1Q�.�.2 Repairs. Application or notice to the buildin� <br /> � �. Side�valks and drivewavs. ofFicial is not required for ordinary repairs to structures, <br /> 6. Painting, papering, tiling, carpetinn, cabinets, counter replacement of lamps or the connection of approved porta- <br /> tops and similar finish work. ble electncal equipment to approved permanently installed <br /> receptacles.Such repairs shall not include the cuetin�away <br /> 7. Prefaoncated swimming poois that are less than 24 of anv wa11,partition or portion thereof.the removal or cut- <br /> � inches(610 mm) deep. tin�of any structura] beam or load-bearing support, or the � <br /> � 8. Swings and other piayground equipment. removal or change of any required means oi e�ress,or rear- <br /> 9. Windov�� awninas supported by an exterior wall which rangement of parts of a structure affectina the e�ress <br /> do not project more than 54 inches(1372 mml irom the requirements;nor shall ordinary repairs include addition to, <br /> exterior wall and do not req,uire additional support. alteration of,replacement or relocation of an��water supply.. <br /> sewer, drainage.drain leader,gas,soil,wasce,vent or simF- <br /> �iectrica�: lar piping, electric winng or mechanical or otner work <br /> Repairs and maintenance: A permit shall not be required for ��ectin�publi�healtn or general safety. <br /> minor repair wor�:, inciuding the replacement of lamps or the K105.?� I'ubiic service a°encies. A permit shall not oe <br /> connection of approved ponable electrical equipment to required for the installation, alteration or repair of�enera- <br /> approved permanentl�� instalied receptacles. tion, transmission, distribution, meterin� or other relaeed � <br /> �a�: eyuipment that is untier the ownership and control of nubIic <br /> 1. Porcable h�atin�,. cookin�� or clothe,�dryin� applianees. <br /> service a��encies by estabIished ri�ht. <br /> ?. P.eviacement of� anv minor part that does not al�er Rl(F�.:�fipnii;ation for permit.To obtain�permit.th�apnli- <br /> , appraval of eQuipmeni ormake such equipment unsare. can�shall first fil�an appii.;ation therefor in wri[in��on a forn� <br /> 3. Portable-tuel-cell appliances that are not connected to a fumisned by tne c'tepar�ment of building safety ior that purpose. <br /> fixed pipin� system and are not interconnected to a <br /> Such appiication shall: <br /> power�rid. L Identify and describe the worlc to be covered by the per- <br /> Mechanicat: mit for which appiication is made. <br /> 1. Portable heatin�appliances. Z. Describe the land on which the proposed work is to be <br /> done b}� le�al description, street address or similar <br /> ?. Portable ventilapon appIiances. � desenption that will readilv identify and definitely locate <br /> 3. Porrable cooling units. � the proposed buildin�or wor}:. <br /> 20d8 1(�6TERNC,Ti.'�NA=R�SlE}cNTI/�!�^.'Ji?=�" ' <br />